Lenze ESMD Series Скачать руководство пользователя страница 4

U V W

L1 L2

8 9 20 28 E1 E2 E3

K14 K12

+10 V

+12 V

COM

AIN

7

8

7

+

_

71 72

L3

7

28 E1 E2 E3

20 A1 62

AOUT

TXA

TXB

COM

DIGOUT

PE

N

L3

L2

L1

3/PE   320V - 0 % … 528V + 0 %

48 Hz … 62 Hz

0.5 Nm/ 4.5 lb-in

6 mm /0.24 in

PES

PE

PES

PES

M

3~

PES

PE

0.2 Nm/ 2 lb-in

6 mm /0.24 in

< 1mm² /AWG 26…16

_

0 … 20 mA
4 … 20 mA

1k … 10k

+12 V DC - 0 %

+30 V DC + 0 %

L1 L2

PE

N

L3

L2

L1

3/PE 180V - 0% … 264V + 0 % 

48 Hz … 62 Hz

L3

1.2 Nm/ 10 lb-in

9 mm /0.35 in

2.0 Nm/ 18 lb-in

13 mm /0.5 in

- 4 -

smd 

series

Installation

L

Connection diagram

R

i

 = 3.3 k

LOW = 0 … +3 V,  HIGH = +12 … +30 V

Protection against contact

All terminals have a basic isolation (single insulating distance)

Protection against contact can only be ensured by additional measures i.e. double insulation

Observe the following when using E.l.c.b:

Installation of E.l.c.b only between supplying mains and controller.

The E.l.c.b can be activated by:
-  capacitive leakage currents between the cable screens during operation (especially with long, screened motor cables)
-  connecting several controllers to the mains at the same time
-  RFI filters

K12

K14

Data for control connections

 (printed in bold = Lenze setting)

Terminal

71
72

7
8

9

20

LOW = Stop     HIGH = Run Enable

28

HIGH = JOG1 active

E1

LOW = CW rotation
HIGH = CCW rotation

E2

HIGH = DCB active

E3

A1

62

(1) Observe the applicable local regulations
(2) Pulse-current or universal-current sensitive earth leakage circuit breaker
(3) UL Class CC fast-acting current-limiting type fuses, 200,000 AIC, required. Bussman KTK-R or equivalent

Fuses/cable cross-sections

(1)

E.l.c.b.

(2)

Installation to EN 60204-1

Installation to UL

Type

ESMD...

L1, L2, L3, PE

[AWG]

Fuse

 (3)

L1, L2, L3, PE

[mm²]

Miniature circuit

breaker

Fuse

> 30 mA

371L4TXA…222L4TXA

14

10 A

1.5

C10 A

M10 A

302L4TXA

14

12 A

1.5

C12 A

M12 A

402L4TXA

14

15 A

2.5

C16 A

M16 A

552L4TXA

12

20 A

2.5

C20 A

M20 A

752L4TXA

10

25 A

4

C25 A

M25 A

552L2TXA, 113L4TXA

8

35 A

6

C35 A

M35 A

752L2TXA, 153L4TXA

8

45 A

10

C45 A

M45 A

183L4TXA

6

60 A

16

C60 A

M60 A

113L2TXA, 223L4TXA

6

70 A

16

C70 A

M70 A

153L2TXA

4

90 A

16

C90 A

M90 A

Relay output (normally-open contact)

Fault (TRIP)

RS-485 serial communication input
RS-485 serial communication input
Reference potential
Analog input

0 … 10 V

 (changeable under C34)

Internal DC supply for setpoint potentiometer
Internal DC supply for digital inputs
Digital input Start/Stop
Digital input configurable with CE1

Activate fixed setpoint 1 (JOG1)

Digital input configurable with CE2

Direction of rotation

Digital input configurable with CE3

Activate DC injection brake (DCB)

Digital output configurable with c17
Analog output configurable with c08 & c11

Modbus or LECOM

input resistance: >50 k

(with current signal: 250 

)

+10 V, max. 10 mA
+12 V, max. 20 mA

AC 250 V / 3 A
DC 24 V / 2 A … 240 V / 0.22 A

DC 24 V / 50 mA; NPN

smd403

Содержание ESMD Series

Страница 1: ...tiometer 6 Set terminal 28 to HIGH and terminal E2 to LOW Response Motor accelerates to setpoint with CW rotation Display shows output frequency in Hz e g 50 50 50 50 50 0 0 0 0 0 7 If necessary optimise settings Faults during commissioning operation see 2 4 5 8 smd401 Type ESMD 93 93 93 114 146 195 114 114 a mm 84 84 84 105 137 183 105 105 a1 mm 146 146 146 146 197 248 146 146 b mm 128 128 128 12...

Страница 2: ...e mechanical stress Do not bend any components and do not change any insulation distances during transport or handling Do not touch any electronic components and contacts Controllers contain electrostatically sensitive components which can easily be damaged by inappropriate handling Do not damage or destroy any electrical components since this might endanger your health Electrical connection When ...

Страница 3: ...oke With active filter in preparation Without additional measures Conformity Approvals Max permissible motor cable length 1 Envionmental conditions Temperature range Installation height Vibration resistance Earth leakage current EN 50178 Enclosure EN 60529 Protection measures against Operation in public supply networks Limitation of harmonic currents according to EN 61000 3 2 Transport Storage Ope...

Страница 4: ...le local regulations 2 Pulse current or universal current sensitive earth leakage circuit breaker 3 UL Class CC fast acting current limiting type fuses 200 000 AIC required Bussman KTK R or equivalent Fuses cable cross sections 1 E l c b 2 Installation to EN 60204 1 Installation to UL Type ESMD L1 L2 L3 PE AWG Fuse 3 L1 L2 L3 PE mm Miniature circuit breaker Fuse 30 mA 371L4TXA 222L4TXA 14 10 A 1 5...

Страница 5: ...IGH see also c70 UP LOW and DOWN LOW quick stop use momentary NC contact CW rotation LOW and CCW rotation LOW Quick stop Controlled deceleration to standstill active LOW LOW CW rotation HIGH CCW rotation Caution C02 1 overwrites all settings Control terminals programming LECOM keypad Control terminals Programming remote keypad Control and programming remote keypad 0 Analog input terminal 8 Selecti...

Страница 6: ... 5 Hz increase C16 until motor current C54 0 8 x rated motor current Set the rated motor frequency nameplate for standard applications C46 C46 C46 C46 C46 C50 C50 C50 C50 C50 C54 C54 C54 C54 C54 Frequency setpoint Output frequency Motor current 255 0 240 0 0 240 0 0 Hz 0 Auto 1 Low C90 C90 C90 C90 C90 0 Input voltage selection C53 C53 C53 C53 C53 DC bus voltage 255 0 999 0 Output frequency at 100 ...

Страница 7: ...11 999 0 0 2 Output frequency 2 10 VDC 1 Output frequency 0 10 VDC c11 c11 c11 c11 c11 0 Configuration analog output 62 5 Dynamic Braking 3 Load 0 10 VDC 4 Load 2 10 VDC Code Possible Settings IMPORTANT No Lenze Name Selection c17 c17 c17 c17 c17 0 Configuration digital output A1 Output is energized if 0 Ready 1 Fault 2 Motor is running 3 Motor is running CW rotation 4 Motor is running CCW rotatio...

Страница 8: ...s active Remote keypad disconnected Short circuit Excessive capacitive charging current of the motor cable Acceleration time C12 too short Defective motor cable Internal fault in motor Frequent and long overload Grounded motor phase Excessive capacitive charging current of the motor cable Motor is thermally overloaded for instance because of impermissable continuous current frequent or too long ac...

Отзывы: