Operation
Control Panel Applets
CAN Gateway
8
46
LDCDS−EL100 EN 8.0
"State" register
EL100−032
Gateway:
Start and stop gateway function
Bus state:
Current state of the CAN system bus (BUS−ON or BUS−OFF)
Bus load (%):
Current bus load
Error state:
Current error
Client connections:
Number of connected Ethernet nodes
Status message interpretation (bus state and error state):
BUS−ON and OK
: CAN communication is alright.
BUS−ON and ERROR:
The warning limit of the CAN controller has been reached or exceeded
(too many error frames). CAN communication is still possible.
BUS−OFF and ERROR:
The CAN controller has reached the BUS−OFF state. CAN
communication is not possible. A reset of the device is required.
"Ethernet" register
EL100−033
Adapter name:
Select the adapter here whose settings are to be displayed.
MAC address, IP address, Subnet mask:
Settings from the "Network and Dial−up
Connections for Ethernet" applet.