Electrical installation
Connection data
55
EDK94AZMP DE/EN/FR/ES/IT 8.0
6.3
Connection data
Mains
Terminal X301
Labelling
Description
L1
L2
L3
Connection of the mains phases L1, L2, L3
Connection for the supply−side PE conductor with M5 ring
cable lug
SSP94NF106
Terminal data
Max. conductor cross−section
Tightening torque
[mm
2
]
[AWG]
[Nm]
[lb−in]
E94AZxP0084
10
6
1.2 ... 1.5
10.6 ... 13.3
PH1
E94AZxP0294
PE connection data
Æ
Starting torque
[mm]
[Nm]
[lb−in]
E94AZxP0084
M5
3
26.5
SW 8
E94AZxP0294
Standard device
Cable X302
Labelling
Description
1
2
3
Filter output conductor (lead with wire end ferrule, colour
BK)
PE
Output−side PE conductor (lead with M5 fork−type cable
lug, colour GN/YE)
SSP94FF007