4
Technical data
4.2
Protocol data
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.2
Protocol data
4.3
Communication time
The communication time is the time between the start of a request and the arrival of the
corresponding response.
The communication times in an PROFINET network depend on the ...
• processing time in the inverter;
• frame runtime (baud rate / frame length);
• nesting depth of the network.
Processing time inside the inverter
There are no interdependencies between parameter data and process data.
Range
Values
Process data words slot 1
1 ... 8 process data words (max. 16 bytes)
Process data words slot 2
(for digital/analog inputs)
Optionally 0, 1, or 2 process data words (max. 4 bytes)
Process input data AI/DI (Slot2) (
Acyclic parameter channel
Limited by the PROFINET frame size
Data
Processing time
Process data
Approx. 2 ms
+ 0 ... 1 ms
+ 1 ... x ms
Update cycle
Processing time in the module
Runtime of the application task of the technology
application used (tolerance)
Parameter data
Approx. 30 ms + a tolerance of 20 ms (typically)
• Some codes may require a longer processing time (see reference manual/
online help for Inverter Drive 8400 motec).