Codetabelle
Important controller codes
l
67
EDS82ZAFIC EN 2.0
10.4
Important controller codes
C0002:
Parameter set management
(extract)
Code
C0002
Name
Parameter set management
Index
0x5FFD (24573)
Subcode
Lenze
Values
Access
Data type
−
0
0
Ready
rw
FIX32
1
Lenze setting
ð
PAR1
rw
FIX32
2
Lenze setting
ð
PAR2
rw
FIX32
3
Lenze setting
ð
PAR3
rw
FIX32
4
Lenze setting
ð
PAR4
rw
FIX32
31
Lenze setting
ð
FPAR1
rw
FIX32
61
Lenze setting
ð
PAR1 + FPAR1
rw
FIX32
62
Lenze setting
ð
PAR2 + FPAR1
rw
FIX32
63
Lenze setting
ð
PAR3 + FPAR1
rw
FIX32
64
Lenze setting
ð
PAR4 + FPAR1
rw
FIX32
þ
Parameter set transfer
In the controller, up to 4 parameter sets (PAR1 ... PAR4) can be saved. In the
function/communication module, 1 parameter set (FPAR1) can be saved.
By means of parameter setting, the parameter set or sets can be defined in which the
delivery status is to be established.