Safety information

1.1

General safety and application notes for Lenze controllers

(according to Low-Voltage Directive 73/23/EEC)

1. General

Lenze controllers (frequency inverters, servo inverters, DC controllers) can carry a voltage or parts of the controllers can rotate during operation. Surfaces can be hot.
If the required cover is removed, the controllers are used inappropriately or installed or operated incorrectly, severe damage to persons or material assets can occur.
For more information please see the documentation.
All operations concerning transport, installation, and commissioning as well as maintenance must be carried out by qualified, skilled personnel (IEC 364 and CENELEC HD

384 or DIN VDE 0100 and IEC report 664 or DIN VDE 0110 and national regulations for the prevention of accidents must be observed).
According to this basic safety information qualified, skilled personnel are persons who are familiar with the assembly, installation, commissioning, and operation of the
product and who have the qualifications necessary for their occupation.

2. Intended use

Drive controllers are components which are designed for the installation into electrical systems or machinery. They are not to be used as domestic appliances, but only
for industrial purposes according to EN 61000-3-2. The documentation contains information about the compliance of the limit values with EN 61000-3-2.
When installing controllers into machines, commissioning of the drive controllers (i.e. the starting of operation as directed) is prohibited until it is proven that the machine

corresponds to the regulations of the EC Directive 98/37/EG (Machinery Directive); EN 60204 (VDE 0113) must be observed.
Commissioning (i.e. starting of operation as directed) is only allowed when there is compliance with the EMC Directive (89/336/EEC).
The drive controllers meet the requirements of the Low-Voltage Directive 73/23/EEC. The harmonised standards EN 50178/DIN VDE 0160 apply to the controllers.
The technical data as well as the connection conditions can be obtained from the nameplate and the documentation. The instructions given must be strictly observed.

Warning:

Controllers are products with restricted availability according to EN 61800-3. These products can cause interferences in residential premises. If controllers are

used in residential premises, corresponding measures are required.

3. Transport, storage

The notes on transport, storage and appropriate handling must be observed.
Climatic conditions according to EN 50178 apply.

4. Installation

The controllers must be installed and cooled according to the regulations given in the corresponding Instructions.
Ensure careful handling and avoid mechanical overload. Do not bend any components and do not change the insulation distances during transport and storage. Electronic
components and contacts must not be touched.
Controllers contain electrostatically sensitive components which can easily be damaged by inappropriate handling. Do not damage or destroy any electrical components

since this could mean hazards for your health!

5. Electrical connection

When working on live controllers, the valid national regulations for the prevention of accidents (e. g. VBG 4) must be observed.
The electrical installation must be carried out in compliance with the corresponding regulations (e.g. cable cross-sections, fuses, PE connection). Additional notes and
information can be obtained from the corresponding Instructions.
The Instructions contain notes concerning wiring according to EMC regulations (shielding, earthing, filters and cable routing). These notes must also be observed when

using CE-marked controllers. The compliance with limit values required by the EMC legislation is the responsibility of the manufacturer of the machine or system.

6. Operation

If necessary, systems including controllers must be equipped with additional monitoring and protection devices according to the applying safety regulations (e.g. regulation

for technical equipment, regulation for the prevention of accidents). The controller can be adapted to your application. Please observe the corresponding information given
in the Instructions.
After a controller has been disconnected from the voltage supply, all live components and power connections must not be touched immediately because capacitors can

still be charged. Please observe the corresponding stickers on the controller.
All protection covers and doors must be shut during operation.

Note for UL-approved systems with integrated controllers:

UL warnings are notes which only apply to UL systems. The Instructions give UL-related information.

7. Safe standstill

The variant V004 of 9300 and 9300 vector, the variant Bx4x of 8200 vector controller and the axis controller ECSXA064 support the function ”Safe standstill”, protection
against unexpected start, according to the requirements of Annex I No. 1.2.7 of the EC Directive ”Machinery” 98/37/EG, DIN EN 954-1 category 3 and DIN EN 1037. Please

observe the notes on the function ”Safe standstill” given in the corresponding Instructions.

8. Maintenance and service

Please observe the Instructions given by the manufacturer.

Please observe the product-specific safety and application notes in these Instructions.

efesotomasyon.com - Lenze

Show/Hide Bookmarks

Содержание E82MV Series

Страница 1: ...Information for the operator of the machine system EDK82MVXXX N Global Drive 8200 motec Frequency inverter 0 25 7 5 kW N efesotomasyon com Lenze Show Hide Bookmarks...

Страница 2: ...o not change the content you are allowed to use the information in this documentation for your purposes without contacting Lenze The information necessary for the project planning of a machine system...

Страница 3: ...50178 apply 4 Installation The controllers must be installed and cooled according to the regulations given in the corresponding Instructions Ensure careful handling and avoid mechanical overload Do n...

Страница 4: ...tools to mount or remove belt pulleys and clutches heat generation and cover them with a touch guard Impermissible belt tensions must be avoided technical list The machines are half key balanced The...

Страница 5: ...L2 L3 can exceed and destroy the input current limit In case of cyclic mains switching over a longer period of time three minutes have to pass between two starting operations Depending on the controll...

Страница 6: ...or monitoring are saved in codes under the menus User and all The codes have numbers 6 and are abbreviated in the text with a C before the number Some codes store the parameters in numerical subcodes...

Страница 7: ...8 0 5 V 0 10 V 0 20 mA C0034 Setpoint selection range 0 Application I O X3 1U 0 5 V 0 10 V X3 2U 0 5 V 0 10 V C0007 Fixed configuration of digital inputs 0 E4 E3 E2 E1 C0007 Fixed configuration of dig...

Страница 8: ...p q r Hi Hz Lo 1 j g f k i h PS 0988 000 000 a b c d e m n op q r Hi Hz Lo 1 j g f k i h PS 0001 000 000 a b c d e m n op q r Hi Hz Lo 1 j g f k i h PS 0007 ALL 000 000 a b c d e m n op q r Hi Hz Lo 1...

Страница 9: ...other are assigned to the same signal source Correct configuration in C0410 Use internal voltage source X3 20 for function modules Standard I O INTERBUS PROFIBUS DP or LECOM B RS485 Bridge between X3...

Страница 10: ...transmitter Increase monitoring time under C0357 3 if necessary ce4 a 65 BUS OFF many communication errors occurred Controller has received too many faulty telegrams via system bus and has been disco...

Страница 11: ...rings OH3 a 53 PTC monitoring TRIP only generated if C0119 1 4 Motor too hot because of impermissibly high current or frequent and long acceleration processes Check drive selection a y g or 4 PTC not...

Страница 12: ...ult Keypad PC 1 rSt a 76 Faulty auto TRIP reset More than 8 fault messages in 10 minutes Depends on the fault message sd5 a 85 Open wire at analog input setpoint range 4 20 mA Current at analog input...

Отзывы: