70
Code Name
Parameter
Accept-
ance
see
page
C228* Acceleration
time (V
z
-
controller)
0.01
Setting range: 0.00...990 s
Step:
0.01 s from 0.00...1 s
0.1 s from 1...10 s
1 s from 10...100 s
10 s from 100...990
ON-LINE
53
C229* Activation
V
z
-controller
-0-
-1-
Mains failure detection with V
z
-control
not activated
Mains failure detection with V
z
-control
activated
53
C236* V
set
(V
z
-controller)
600
Setting range: 300...900 V
Step:
1 V
ON-LINE
53
C237* Influence of
V
z
-control
1000
Setting range: 1...8000 rpm
Step:
1 rpm
ON-LINE
53
C249
(L)
LECOM1-code
bank
-0-
-1-
-2-
-3-
-4-
-5-
-6-
-7-
C000 to C255
C250 to C505
C500 to C755
C750 to C1005
C1000 to C1255
C1250 to C1505
C1500 to C1755
C1750 to C2000
SH+PRG
C250* Homing mode
-0-
-1-
not active
active
56
C252* Angle offset
0
Setting range: 0...2047
Step:
1
ON-LINE
56
C253* Speed-
proportional
angle offset
8.5
Setting range: -819.1...+819.1 incre-
ments (at 4000 rpm)
Step:
1
Possibility to correct an angular
offset, which is proportional to the
speed and depending on the cycle
time. The setting refers to an
incremental deviation of 4000 rpm.
ON-LINE
C254* V
pw
14
Setting range: 0...16
Step:
1
ON-LINE
56
C255* Following error
limit
10
Setting range: 10...3071 increments
Step:
1 increment
ON-LINE
57
Содержание 9212
Страница 3: ...EDB9200_E GB 00375316 Antriebstechnik Operating Instructions Servo controller 9200 series ...
Страница 32: ...28 5 2 Wiring with positioning control SX 1 5 2 1 Diagram 1 Mains supply ...
Страница 33: ...29 5 2 2 Diagram 2 Control circuit 230V ...
Страница 34: ...30 5 2 3 Diagram 3 Control circuit 24V ...
Страница 35: ...31 5 2 4 Diagram 4 Control connections 9200 SX1 Ω ...
Страница 36: ...32 5 2 5 Diagram 5 Control connections SX1 ...
Страница 59: ...55 Signal fow chart DC bus control ...