42
Acceptance with SH + PRG with controller inhibit
The axis module accepts the new parameter when it has been
inhibited prior to pressing SH + PRG. Inhibit the controller e.g. by
pressing STP. First press SH and then in addition PRG. The
display shows --ok-- for 0.5 seconds. The axis module works with
the new parameter when the controller is released again. If you
have to set a parameter of a code in this way, the symbol
appears in the code table.
2.2.
Save parameters
•
When commissioning for the first time, the parameter set 1 is
factory-set. After the acceptance, new parameters are saved in
the RAM, i.e. they are saved until the controller is disconnected
from the mains.
If you do not want to lose your setting when connecting the
controller to the mains, save them permanently:
1. Select code C003.
2. Select parameter set 1 by entering -1- .
3. Press SH first, and then additionally PRG. --ok-- will be
displayed.
4. Now you can disconnect the servo controller from the mains.
Your settings are permanently saved under "parameter set
1".
•
Password
The input of a password prevents unauthorized changes of
parameters or code levels.
2.3.
Load parameter
If you only need one parameter set, you can permanently save
your changes under parameter set 1. After every mains connection,
parameter set 1 is loaded automatically.
Содержание 9212
Страница 3: ...EDB9200_E GB 00375316 Antriebstechnik Operating Instructions Servo controller 9200 series ...
Страница 32: ...28 5 2 Wiring with positioning control SX 1 5 2 1 Diagram 1 Mains supply ...
Страница 33: ...29 5 2 2 Diagram 2 Control circuit 230V ...
Страница 34: ...30 5 2 3 Diagram 3 Control circuit 24V ...
Страница 35: ...31 5 2 4 Diagram 4 Control connections 9200 SX1 Ω ...
Страница 36: ...32 5 2 5 Diagram 5 Control connections SX1 ...
Страница 59: ...55 Signal fow chart DC bus control ...