Electrical installation
Wiring
Mains choke/mains filter assignment
116
EDK82EV222 DE/EN/FR 13.0
Operation at rated power on 400/500 V mains, 3/PE
8200 vector
Mains choke
I
nterference voltage category (EN 61800−3) and motor cable
length
Component
Component
Type
Var.
Type
C2
Max.
[m]
C1
Max.
[m]
E82xV551K4C
0
xx
EZAELN3002B153
−
20
−
1)
2
xx
E82ZZ75134B200
20
E82ZZ75134B200
20
E82ZZ75134B210
50
E82ZZ75134B210
50
E82xV751K4C
0
xx
EZAELN3004B742
−
20
−
1)
2
xx
E82ZZ75134B200
20
E82ZZ75134B200
20
E82ZZ75134B210
50
E82ZZ75134B210
50
E82xV152K4C
0
xx
EZAELN3004B742
−
20
−
1)
2
xx
E82ZZ22234B200
20
E82ZZ22234B200
20
E82ZZ22234B210
50
E82ZZ22234B210
50
E82xV222K4C
0
xx
EZAELN3006B492
−
20
−
1)
2
xx
E82ZZ22234B200
20
E82ZZ22234B200
20
E82ZZ22234B210
50
E82ZZ22234B210
50
1)
The motor cable length depends on the inverter type and the switching frequency
Operation with increased rated power