![Lenz Digital plus LF101XF Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/lenz/digital-plus-lf101xf/digital-plus-lf101xf_manual_1881848009.webp)
LF101XF function decoder
9
C
V
Value
/ Bit
Description
Default
setting
C
V
Function
output:
A
B
C
D
E
F
33
0-255 F0 forward
8
16 32 64 128
0
34
0-255 F0
backward
8
16 32 64 128
0
35
0-255 Function 1
8
16 32 64 128
8
36
0-255 Function 2
8
16
32 64 128
16
37
0-255 Function 3
8
16
32
64 128
32
38
0-255 Function 4
1
2
4
8
16
32
8
39
0-255 Function 5
1
2
4
8
16
32
16
40
0-255 Function 6
1
2
4
8
16
32
32
41
0-255 Function 7
1
2
4
8
16
32
0
42
0-255 Function 8
1
2
4
8
16
32
0
43
0-255 Function 9
1
2
4
0
44
0-255 Function
10
1
2
4
0
45
0-255 Function
11
1
2
4
0
46
0-255 Function
12
1
2
4
0
If a function is to have an effect on several
function outputs, the values found at the
intersections must be added up and the result
written into the CV.
Example:
Function outputs C and D are to be
switched with function 1. You must add up the
two values found at the intersections of row
CV35/Function 1 and the columns Function
output D and C and enter the result in CV35:
32+64=
96
.
49
Bit
Polarity-dependent lighting for
outputs A and B
1 (0) 1 Outputs A and B change their polarity
depending on the direction of motion. In the
forward direction, output A is the negative
pole, in the backward direction, output B is
the negative pole.
0 Outputs A and B do not change their polarity
and act as normal functions activated by the
values in CVs 33-42.
1