Locomotive decoder LE080XS
7
DIGITAL plus
Table 1: LE080XS Configuration Variables
CV
R
e
g
Description
Range
Factory
setting
1
1
Locomotive address:
This is the number with which you select a
locomotive in the DIGITAL plus system.
Setting the address from #1 to #3 using register
mode will reset the decoder to utilize 14 speed
step operation.
1-127
3
2
2
Start voltage:
This is the voltage applied to the motor in speed
step 1. Set this value so that the locomotive just
starts moving in speed step 1.
0-31
8
3
3
Acceleration Momentum:
Determines the rate of change of speed upon
acceleration. A higher value leads to a slower
acceleration.
1-31
1
4
4
Brake Momentum:
Determines the rate of change of speed upon
braking. A higher value leads to longer brake
distance.
1-31
1
-
5
Contains CV29 (see CV29 below)
0-55
6
-
6
Page Register:
Normally this CV is not modified directly by a
user. For correct operation, this CV should be
set to have a value of 1 after any use.
0-127
1
7
7
Version Number:
This location stores the version number of the
decoder. This location is read only.
-
45
8
8
Manufacturers Identification / Factory reset
This value is the manufacturer ID of the decoder,
(Lenz =99). Writing a value of 33 using Register
mode resets all CVs to their factory condition
-
99
17
-
Extended Address High Byte
192-
231
0
18
-
Extended Address Low Byte
The two byte address if used is contained in
CV17+18
0-255
0
19
-
Consist Address
The advanced consist address if used is stored
in CV19
0-255
0
23
-
Acceleration Trim This Configuration Variable
contains additional acceleration rate information
that is to be added to or subtracted from the
base value contained in CV3
0-255
255
**Note: in the factory setting field the numbers in the () are decimal.