LC100 XpressNET Converter
3
DIGITAL plus
Connecting the LC100 to a "foreign" DCC System
The connections to the LC100 are always according to the same
principle, independent of the other digital device:
The terminals that connect the other digital system to the tracks
is connected to the screw terminals labeled "Gleisanschluß
central unit=" on the LC100, as illistrated in figures 1 and 2.
Please switch off the supply voltage to the digital system before
connecting to the LC100. (Disconnect the power lines from the
wall plug)!
Connecting the LC100 to X
press
NET
The terminal connecting the LC100 to the
X
press
NET
is located
on the right hand side of the unit. Please connect the four poles
(L, M, A, B) on this screw terminal with the identical terminals on
the Command Station LZ100 or LA152, or using an
X
press
NET
X
press
NET
port on your system
The connection does not need to be directly to the Command
Station, but can be done at any point on the
X
press
NET
, for
example at a connector plate LA150/151. As always, when wiring
an
X
press
NET
extension, the cables L and M and the cables A
and B have to be laid out as a twisted pair.
Now you can reconnect the supply voltage to your
X
press
NET
based system and also to the other digital system.