System x3650 M5
47
Models with 750 W Platinum AC power supplies:
100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 8.6 A
200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 4.2 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.15 kVA
Maximum configuration: 1.015 kVA
Models with 750 W Titanium AC power supplies:
200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 4.2 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.15 kVA
Maximum configuration: 0.965 kVA
Models with 550 W AC power supplies:
100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 6.5 A
200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 3.3 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.16 kVA
Maximum configuration: 0.732 kVA
Models with -48Vdc 900 W power supplies:
-48 - -60 (nominal) V dc; 25.8 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.15 kVA
Maximum configuration: 1.237 kVA
BTU output:
Minimum configuration: 525 Btu/hr (154 watts)
Maximum configuration: 6667 Btu/hr (1954 watts)
Noise level:
6.6 bels (operating)
6.4 bels (idle)