Drive
connectivity
Dual-ported 12 Gb SAS drive attachment infrastructure.
Controller unit with two node canisters (ports per one node canister):
24x 12 Gb SAS internal drive ports (SFF enclosure)
12x 12 Gb SAS internal drive ports (LFF enclosure)
1x 12 Gb SAS x4 (Mini-SAS HD SFF-8644) expansion port for the attachment of the
expansion enclosures
Expansion unit with two expansion canisters (ports per one expansion canister):
24x 12 Gb SAS internal drive ports (SFF enclosure)
12x 12 Gb SAS internal drive ports (LFF enclosure)
2x 12 Gb SAS x4 (Mini-SAS HD SFF-8644) expansion ports for the daisy chained
attachment of the expansion enclosures
Drives
SFF drives:
300 GB and 600 GB 15K rpm SAS HDDs
900 GB, 1.2 TB, and 1.8 TB 10K rpm SAS HDDs
2 TB 7.2K rpm NL SAS HDDs
400 GB, 800 GB, 1.6 TB, and 3.2 TB SAS SSDs
1.92 TB and 3.84 TB read-optimized SAS SSDs
LFF drives:
300 GB and 600 GB 15K rpm SAS HDDs
900 GB, 1.2 TB, and 1.8 TB 10K rpm SAS HDDs
4 TB, 6 TB, and 8 TB 7.2K rpm NL SAS HDDs
Storage capacity Up to 960 TB (120x 8 TB NL SAS HDDs)
Host
connectivity
Standard ports (per control enclosure with two node canisters):
4x 1 Gb iSCSI host ports (UTP, RJ-45) (2 ports per node canister)
4x 12 Gb SAS host ports (Mini-SAS HD, SFF-8644) (2 ports per node canister; V3700
V2 XP only)
Optional additional ports on host interface cards (per control enclosure with two node
canisters):
8x 12 Gb SAS host ports (Mini-SAS HD, SFF-8644) (4 ports per node canister)
8x 1 Gb iSCSI host ports (UTP, RJ-45) (4 ports per node canister)
8x 10 Gb iSCSI or FCoE SFP+ host ports (SW fiber, LC) (4 ports per node canister)
8x 16 Gb FC SFP+ host ports (SW or LW fiber, LC) (4 ports per node canister)
Host operating
systems
Microsoft Windows Server 2012 and 2012 R2; Red Hat Enterprise Linux (RHEL) 6 and 7; SUSE
Linux Enterprise Server (SLES) 11 and 12; VMware vSphere 5.1, 5.5, and 6.0.
Standard
software
features
Virtualization of internal storage, Thin Provisioning, One-way Data Migration, FlashCopy
snapshots (up to 64 targets), and Embedded GUI.
Optional
software
features
FlashCopy snapshots upgrade (up to 2048 targets), Easy Tier, and Remote Mirroring.
Performance
(V3700 V2 /
V3700 V2 XP)*
Up to 168,000 / 390,000 cache read IOPS
Up to 51,000 / 112,000 disk read IOPS
Up to 13,000 / 28,000 disk write IOPS
Up to 27,000 / 55,000 disk mixed (70% read/30% write) IOPS
Up to 3.4 / 6.2 GBps sequential disk read throughput
Up to 0.96 / 1.7 GBps sequential disk write throughput
Component
Specification
Lenovo Storage V3700 V2 and V3700 V2 XP
6
Проконсультироваться
и
купить
данное
оборудование
вы
можете
в
компании
«
АНД
-
Системс
»
адрес
: 125480,
г
.
Москва
,
ул
.
Туристская
,
д
.33/1; site: https://andpro.ru
тел
: +7 (495) 545-4870 email: [email protected]
При
обращении
используйте
промокод
AND-PDF
и
получите
скидку
.