Port Link LED Is Not Lit
Symptom:
The port link LED is not lit.
Solution 1:
Check the port configuration in the firmware (see the
Command
Reference
). If the port is configured with a specific speed or duplex mode, check the
other device to make sure that it is set to the same configuration. If the switch port is
set to auto-negotiate, make sure that the other device is set to auto-negotiate.
Solution 2:
Check the cables that connect the port to the other device. Make sure
that they are connected correctly. Make sure that you are using the correct cable
type.