Note:
The illustrations in this topic show how to install and remove the TMM on the AnyRAID Adapter. For
the RAID 720i PCIe Adapter, the procedure is similar.
Installing the TMM
Attention:
Do not open your server or attempt any repair before reading and understanding “Read this first: safety
information” on page iii and “Guidelines” on page 69.
Before you begin, print all the related instructions or ensure that you can view the PDF version on another
computer for reference.
Notes:
• Use any documentation that comes with the TMM and follow those instructions in addition to the
instructions in this topic.
• Depending on the specific type, your AnyRAID adapter and TMM might look different from the illustration
in this topic.
To install the TMM, do the following:
1. Remove all external media from the drives and turn off all attached devices and the server. Then,
disconnect all power cords from electrical outlets and disconnect all cables that are connected to
the server.
2. If the server is installed in a rack cabinet, remove the server from the rack cabinet and place it on a flat,
clean, and static-protective surface. See the
Rack Installation Instructions
that comes with the server. If
the server is in tower form factor, lay the server on its side for easier operation.
3. Remove the server cover. See “Removing the server cover” on page 72.
4. Locate the AnyRAID adapter or the RAID 720i PCIe Adapter.
5. Align the two holes in the TMM with the two pins on the AnyRAID adapter or the RAID 720i PCIe
adapter. Then, lower the TMM straight down until it is securely seated.
Note:
If necessary, remove the AnyRAID adapter or the RAID 720i PCIe adapter first for easier operation.
After you install the TMM, reinstall the adapter. See “Replacing the AnyRAID adapter” on page 159. or
“Installing or removing a PCIe card” on page 90.
Figure 63. Installing the TMM
What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To complete the installation, go to “Completing the parts replacement” on page 180.
105
Содержание ThinkServer TD350
Страница 14: ...xii ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Страница 18: ...4 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Страница 20: ...6 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Страница 206: ...192 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Страница 213: ...China RoHS Appendix A Notices 199 ...
Страница 224: ...210 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Страница 225: ......
Страница 226: ......