Heat sink
•
“Removing the heat sink” on page 52
•
“Installing the heat sink” on page 53
CAUTION:
The heat sink might be very hot. Turn off the server and wait three to five minutes to let the server
cool before removing the server cover.
Removing the heat sink
To remove the heat sink, do the following:
1. Prepare your server. See “Preparing your server in advance” on page 47.
2. Remove the air baffle. See “Removing the air baffle” on page 50.
3. Locate the heat sink and remove the four screws that secure the heat sink. It is recommended that
you carefully remove the four screws from the system board using the following method to avoid any
possible damage to the system board.
a. Partially remove screw
1
, then completely remove screw
2
, and then return to screw
1
and
completely remove it.
b. Partially remove screw
3
, then completely remove screw
4
, and then return to screw
3
and
completely remove it.
Note:
The four screws are integrated parts of the heat sink. Do not try to remove the four screws
from the heat sink.
Figure 24. Removing the screws that secure the heat sink
4. Gently twist the heat sink to free it from the microprocessor, lift the heat sink off the system board, and
then lay it down by its side. Do not touch the thermal grease on the bottom of the heat sink.
52
ThinkServer RS160 User Guide and Hardware Maintenance Manual
Содержание ThinkServer RS160
Страница 1: ...ThinkServer RS160 User Guide and Hardware Maintenance Manual Machine Types 70TD 70TE 70TF and 70TG ...
Страница 14: ...xii ThinkServer RS160 User Guide and Hardware Maintenance Manual ...
Страница 18: ...4 ThinkServer RS160 User Guide and Hardware Maintenance Manual ...
Страница 42: ...28 ThinkServer RS160 User Guide and Hardware Maintenance Manual ...
Страница 58: ...44 ThinkServer RS160 User Guide and Hardware Maintenance Manual ...
Страница 118: ...104 ThinkServer RS160 User Guide and Hardware Maintenance Manual ...
Страница 129: ...Taiwan BSMI RoHS declaration Appendix C Restriction of Hazardous Substances RoHS Directive 115 ...
Страница 130: ...116 ThinkServer RS160 User Guide and Hardware Maintenance Manual ...
Страница 141: ......
Страница 142: ......