Serial-device
problems
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
the
parts
listing
in
the
Hardware
Maintenance
Manual
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Symptom
Action
The
number
of
serial
ports
that
are
identified
by
the
operating
system
is
less
than
the
number
of
installed
serial
ports.
1.
Make
sure
that:
v
Each
port
is
assigned
a
unique
address
in
the
Configuration/Setup
Utility
program
and
none
of
the
serial
ports
is
disabled.
v
The
serial-port
adapter
(if
one
is
installed)
is
seated
correctly.
2.
Reseat
the
serial
port
adapter.
3.
Replace
the
serial
port
adapter.
A
serial
device
does
not
work.
1.
Make
sure
that:
v
The
device
is
compatible
with
the
server.
v
The
serial
port
is
enabled
and
is
assigned
a
unique
address.
v
The
device
is
connected
to
the
correct
connector
(see
“Rear
view”
on
page
28).
2.
Reseat
the
following
components:
a.
Failing
serial
device
b.
Serial
cable
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Failing
serial
device
b.
Serial
cable
c.
(Trained
service
technician
only)
System
board
EasyStartup
problems
Table
5.
EasyStartup
DVD
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
Column
until
the
problem
is
resolved.
v
See
the
Hardware
Maintenance
Manual
on
the
Documentation
DVD
to
determine
which
components
are
customer
replaceable
units
(CRU’s)
and
which
fields
are
field
replacable
units
(FRU’s).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Symptom
Action
The
EasyStartup
DVD
will
not
start.
v
Make
sure
that
the
server
supports
the
EasyStartup
program
and
has
a
startable
(bootable)
CD
or
DVD
drive.
v
If
the
startup
(boot)
sequence
settings
have
been
changed,
make
sure
that
the
CD
or
DVD
drive
is
first
in
the
startup
sequence.
v
If
more
than
one
CD
or
DVD
drive
is
installed,
make
sure
that
only
one
drive
is
set
as
the
primary
drive.
Start
the
CD
from
the
primary
drive.
The
ServeRAID
Manager
program
cannot
view
all
installed
drives,
or
the
operating
system
cannot
be
installed.
v
Make
sure
that
the
hard
disk
drive
is
connected
correctly.
v
Make
sure
that
the
SAS
hard
disk
drive
cables
are
securely
connected.
54
ThinkServer
RS110
Types
6435,
6436,
6437,
and
6438:
Installation
Guide
Содержание ThinkServer RS110 Type 6435
Страница 1: ...ThinkServer RS110 Types 6435 6436 6437 and 6438 Installation Guide ...
Страница 2: ......
Страница 3: ...ThinkServer RS110 Types 6435 6436 6437 and 6438 Installation Guide ...
Страница 14: ...xii ThinkServer RS110 Types 6435 6436 6437 and 6438 Installation Guide ...
Страница 24: ...10 ThinkServer RS110 Types 6435 6436 6437 and 6438 Installation Guide ...
Страница 50: ...36 ThinkServer RS110 Types 6435 6436 6437 and 6438 Installation Guide ...
Страница 74: ...60 ThinkServer RS110 Types 6435 6436 6437 and 6438 Installation Guide ...
Страница 86: ...72 ThinkServer RS110 Types 6435 6436 6437 and 6438 Installation Guide ...
Страница 87: ......
Страница 88: ...Part Number 46U0855 Printed in USA 1P P N 46U0855 ...