Attention:
To
avoid
damage
to
the
hard
disk
drive
connectors,
make
sure
that
the
cover
is
in
place
and
fully
closed
whenever
you
install
or
remove
a
hard
disk
drive.
1.
Read
the
safety
information
that
begins
on
page
v
and
“Installation
guidelines”
on
page
11.
2.
Make
sure
that
the
server
cover
is
in
place
and
fully
closed.
3.
Remove
the
filler
panel
3
from
the
bay.
Store
it
in
a
safe
place
for
possible
future
use.
Attention:
To
maintain
proper
system
cooling,
do
not
operate
the
server
for
more
than
10
minutes
without
either
a
drive
or
filler
panel
installed
in
each
bay.
4.
Open
the
drive
tray
handle
2
.
5.
Gently
push
the
drive
assembly
1
into
the
bay
until
the
drive
stops.
6.
Close
the
drive
tray
handle.
7.
Check
the
hard
disk
drive
status
LED
to
make
sure
that
the
hard
disk
drive
is
operating
correctly.
If
the
amber
hard
disk
drive
status
LED
for
a
drive
is
lit
continuously,
that
drive
is
faulty
and
must
be
replaced.
If
the
green
hard
disk
drive
activity
LED
is
flashing,
the
drive
is
being
accessed.
If
you
have
other
devices
to
install,
do
so
now.
Otherwise,
go
to
“Completing
the
installation”
on
page
24.
Installing
an
adapter
The
following
notes
describe
the
types
of
adapters
that
the
server
supports
and
other
information
that
you
must
consider
when
you
install
an
adapter:
v
Locate
the
documentation
that
comes
with
the
adapter
and
follow
those
instructions
in
addition
to
the
instructions
in
this
section.
If
you
have
to
change
switch
settings
or
jumper
settings
on
the
adapter,
follow
the
instructions
that
come
with
the
adapter.
v
The
adapter
slots
are
on
the
riser-card
assembly.
You
must
first
remove
the
riser-card
assembly
to
access
the
adapter
slots.
v
The
two
PCI
Express
slots
on
the
riser-card
assembly
support
PCI
Express
x8
1.0a
adapters.
v
You
can
install
one
full-height
three-quarter-length
adapter
in
expansion
slot
1
and
one
low-profile
half-length
adapter
in
expansion
slot
2.
Note:
When
the
optional
Remote
Supervisor
Adapter
II
SlimLine
is
installed
in
the
server,
you
can
install
only
a
half-length
adapter
in
expansion
slot
1.
v
If
you
have
installed
an
optional
PCI-X
riser-card
assembly
in
the
server,
you
can
install
a
full-height,
three-quarter-length
PCI-X
64/133
MHz
adapter
in
the
PCI-X
slot
on
the
riser-card
assembly.
Note:
When
the
optional
Remote
Supervisor
Adapter
II
SlimLine
is
installed
in
the
server,
you
can
install
only
a
half-length
adapter
in
the
PCI-X
slot.
v
The
optional
Remote
Supervisor
Adapter
II
SlimLine
can
be
installed
only
in
the
dedicated
connector
on
the
system
board
(see
“System-board
optional-device
connectors”
on
page
9
for
the
location
of
the
connector).
To
install
the
Remote
Supervisor
Adapter
II
SlimLine,
see
“Installing
an
IBM
®
Remote
Supervisor
Adapter
II
SlimLine”
on
page
22.
v
The
server
uses
a
rotational
interrupt
technique
to
configure
PCI
Express
adapters
so
that
you
can
install
PCI
Express
adapters
that
do
not
support
sharing
of
interrupts.
18
ThinkServer
RS110
Types
6435,
6436,
6437,
and
6438:
Installation
Guide
Содержание ThinkServer RS110 Type 6435
Страница 1: ...ThinkServer RS110 Types 6435 6436 6437 and 6438 Installation Guide ...
Страница 2: ......
Страница 3: ...ThinkServer RS110 Types 6435 6436 6437 and 6438 Installation Guide ...
Страница 14: ...xii ThinkServer RS110 Types 6435 6436 6437 and 6438 Installation Guide ...
Страница 24: ...10 ThinkServer RS110 Types 6435 6436 6437 and 6438 Installation Guide ...
Страница 50: ...36 ThinkServer RS110 Types 6435 6436 6437 and 6438 Installation Guide ...
Страница 74: ...60 ThinkServer RS110 Types 6435 6436 6437 and 6438 Installation Guide ...
Страница 86: ...72 ThinkServer RS110 Types 6435 6436 6437 and 6438 Installation Guide ...
Страница 87: ......
Страница 88: ...Part Number 46U0855 Printed in USA 1P P N 46U0855 ...