event type

event Level String

notification 

Area icon

event Log e-mail 

notification

Disk triggered events

failed

Error

Disk on port {n}: failed. Open the application for details. Yes

Yes

Yes

S.M.A.R.T.

Warning

Disk on port {n}: At risk. Open the application for details. Yes

Yes

Yes

Unlocked

Info

Disk on port {n}: Unlocked.

Yes

Yes

Yes

Added

Info

Disk on port {n}: Detected.

Yes

Yes

Yes

Removed

Info

Disk on port {n}: Removed.

Yes

Yes

Yes

rAiD volume triggered events

failed

Error

Volume {n}: failed. Open the application for details.

Yes

Yes

Yes

Degraded

Warning

Volume {n}: Degraded. Open the application for details.

Yes

Yes

Yes

Detected

Info

A new volume was found.

Yes

Yes

Yes

RebuildComplete

Info

Volume {n}: Rebuilding complete.

Yes

Yes

Yes

VerifyStop

Info

Volume {n}: Verification complete.

Yes

Yes

Yes

Verify
AndRepairStop

Info

Volume {n}: Verification and repair complete.

Yes

Yes

Yes

MigrationComplete

Info

Volume {n}: Data migration complete.

Yes

Yes

Yes

InitializeComplete

Info

Volume {n}: Initialization complete.

Yes

Yes

Yes

Unlocked

Info

Volume {n}: Unlocked.

Yes

Yes

Yes

NotPresent

Info

Volume {n}: No longer present on system.

Yes

Yes

Yes

RebuildStarted

Info

Volume {n}: Rebuilding in progress.

Yes

No

No

VerifyStarted

Info

Volume {n}: Verification in progress.

Yes

No

No

VerifyAndRepairStarted Info

Volume {n}: Verification and repair in progress.

Yes

No

No

MigrationStarted

Info

Volume {n}: Data migration in progress.

Yes

No

No

InitializeStarted

Info

Volume {n}: Initialization in progress.

Yes

No

No

general events

Server start failed

Error

Server failed to start.  Additional information:

No

Yes

Yes

Event manager started

Info

Started the event manager

No

Yes

Yes

AppenDix – monitor ServiCe event DeteCtion

©2011 Lenovo. All rights reserved.

Availability: Offers, prices, specifications and availability may change without notice. Lenovo is not responsible for photographic or typographic errors. Warranty: for a copy of applicable warranties, write to: Warranty Information, 500 Park Offices Drive, RTP, 
NC, 27709, Attn: Dept. ZPYA/B600. Lenovo makes no representation or warranty regarding third-party products or services. Trademarks: Lenovo, the Lenovo logo, Rescue and Recovery, ThinkStation, ThinkVantage, and ThinkVision are trademarks or registered 
trademarks of Lenovo. Microsoft, Windows, and Vista are registered trademarks of Microsoft Corporation. Intel, the Intel logo, Intel Core, Core Inside, Xeon and Xeon Inside are registered trademarks of Intel Corporation in the U.S. and other countries. Other company, 
product, and service names may be trademarks or service marks of others. Visit www.lenovo.com/safecomputing periodically for the latest information on safe and effective computing. 

Содержание ThinkServer RAID 100

Страница 1: ... 07 Matrix RAID 07 Delete RAID Volume 07 Reset Disks to Non RAID 07 RAID Ready 07 Recovery Volume 07 Driver Installation 07 Manually Installing the Driver During OS Installation 07 Manually Installing the Driver After OS Installation 09 Managing ThinkServer RAID 100 on TS130 10 Installing the Storage Management Console 11 Using the Storage Management Console 13 Appendix Monitor Service Event Detec...

Страница 2: ...k drive or virtual drive The RAID level will be assigned to the array Choosing the RAID Level The RAID configuration selected should be based on consideration of several factors the most important being performance and fault tolerance Maximize virtual drive performance by creating a RAID 0 array with striping Data is broken into segments and is simultaneously written to or read from several differ...

Страница 3: ... capacity equal to that of the smaller hard drive2 1 2 This capacity statement assumes that only one RAID volume is configured in the array Two RAID volumes are supported per array see the section on Matrix RAID for more information This section provides a basic overview of the steps required to setup and configure a RAID array on TS130 BIOS Setup Configure BIOS for RAID operation The SATA control...

Страница 4: ...ot be available Hard Disk Pre delay can be set to Disabled the default 6 To accept the changes press F10 and select Yes when prompted to Save Configuration and Exit Configure RAID using the pre boot configuration utility 1 If BIOS was just configured for RAID operation the TS130 will soon restart itself Otherwise reboot the TS130 If two HDD s are installed and the SATA controller was configured fo...

Страница 5: ...w keys to select from the menu 1 Create RAID Volume and press ENTER key to enter the Create Volume Menu 3 Type a name for the new RAID volume to be created In this example the default Volume0 is used 4 Press TAB to move to the next entry Select the RAID Level from the selection using the up and down arrow keys In this example select RAID0 Stripe 5 Press TAB to move to the next entry Enter the stri...

Страница 6: ...D 1 volume on the same disks 7 Press TAB to highlight Create Volume and Press ENTER to create the specified volume A warning message will pop up on screen Confirm that any previous data on the drives is no longer needed Press Y to create the new RAID volume or press N to cancel the operation 8 After the RAID volume is created the main menu is displayed Disk Volume Information displays key informat...

Страница 7: ...d Storage User Interface Management Console GUI application This process does not require the reinstallation of the operating system All applications and data will remain intact Recovery Volume A recovery volume is a RAID like configuration that utilizes RAID 1 functionality to copy data from a designated Master drive to a designated Recovery drive The data on the master drive is configured to upd...

Страница 8: ...ight require changes to allow CD ROM booting See your system documentation 2 Begin the Operating System installation selecting the language the OS version to install and finally reading and accepting the license agreement 3 When presented with the screen What type of installation do you want select Custom advanced install 4 To install the driver click Load Driver 5 Insert the media that contains t...

Страница 9: ...stallation Manually Installing the Driver after OS Installation Perform the following steps to install the device driver after the OS has been installed or to upgrade a driver to a newer version The driver installation automatically adds the driver to the registry and copies the driver to the appropriate directory 1 To install the driver manually launch the Device Manager in the Operating System 2...

Страница 10: ... User Interface software is a utility that enables configuration monitoring and maintenance of storage configurations This section gives a basic overview of the storage management console how to manage arrays and how to setup alerts and notifications Additional information is available from the Help menu from within the application Rapid Storage Technology User Interface can be downloaded from the...

Страница 11: ...enables the creation and deletion of RAID volumes as well as other configuration and management features that the pre boot Configuration Utility does not support Microsoft NET 3 5 is a prerequisite to the installation of the management console Microsoft Windows Server 2008 R2 already includes the installation of NET 3 5 but it must be enabled prior versions of Windows Server OS require that it be ...

Страница 12: ...Configuring RAID 100 on TS130 12 To learn more go to www lenovo com thinkserver 4 Click Next 5 Click Next 6 Click Install 7 Installation of the selected features and roles will begin ...

Страница 13: ...d Using the Storage Management Console The Storage management Console can be used to locally manage RAID volumes and member drives as well as configure alerts and notifications This section gives a basic overview of these capabilities 1 When the system is active a notification icon in the system tray reports basic health status of the RAID array and the member drives Clicking the icon will open th...

Страница 14: ...DD 5 In the Preferences tab System Preferences allows configuration of the types of notifications to be indicated locally in the system tray notification icon see the 6 Appendix Monitor Service Event Detection for a list of supported events Select from the choices provided or disable notifications completely 7 In the Preferences tab E mail Preferences enables configuring the platform to send alert...

Страница 15: ...oices provided to choose the types of notifications to be sent to an email address or disable notifications completely If notifications are selected also provide the e mail configuration settings SMTP host required Port required Return email address required Recipient email addresses one address required up to 3 maximum Test e mails can be sent to all addresses specified ...

Страница 16: ...ifyStarted Info Volume n Verification in progress Yes No No VerifyAndRepairStarted Info Volume n Verification and repair in progress Yes No No MigrationStarted Info Volume n Data migration in progress Yes No No InitializeStarted Info Volume n Initialization in progress Yes No No General Events Server start failed Error Server failed to start Additional information No Yes Yes Event manager started ...

Отзывы: