Diagnostic Error Code
FRU/Action
005-197-XXX
Video test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using the
Setup Utility program” on page 39
2. Re-run test
3. Replace the component called out in warning
statement
4. Replace the component under test
005-198-XXX
Video test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using the
Setup Utility program” on page 39
2. Flash the system and re-test. See “Updating
(flashing) BIOS from a disc” on page 98
3. Go to “Undetermined problems” on page 64
005-199-XXX
Video test failed, cause unknown
1. Go to “Undetermined problems” on page 64
2. Flash the system and re-test. See “Updating
(flashing) BIOS from a disc” on page 98
3. Replace component under function test
005-2XX-XXX 005-3XX-XXX
Video subsystem error
1. Video card, if installed
2. System board
006-000-XXX
Diskette interface Test Passed
No action
006-0XX-XXX
Diskette interface error
1. Diskette drive Cable
2. Diskette drive
3. System board
006-195-XXX
Diskette interface Test aborted by user
Information only Re-start the test, if necessary
006-196-XXX
Diskette interface test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
006-197-XXX
Diskette interface test warning
1. If a component is called out, make sure it is
connected and/or enabled
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
006-198-XXX
Diskette interface test aborted
1. If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test. See “Updating
(flashing) BIOS from a disc” on page 98
3. Go to “Undetermined problems” on page 64
006-199-XXX
Diskette interface test failed, cause
unknown
1. Go to “Undetermined problems” on page 64
2. Flash the system and re-test
3. Replace component under function test
006-25X-XXX
Diskette interface Error
1. Diskette drive cable
2. Diskette drive
3. System board
011-000-XXX
Serial port Interface Test Passed
No action
Chapter 7
.
Symptom-to-FRU index
49
Содержание ThinkCentre M90p
Страница 1: ...ThinkCentre Hardware Maintenance Manual Machine Type 7536 ...
Страница 2: ......
Страница 3: ...ThinkCentre Hardware Maintenance Manual Machine Type 7536 ...
Страница 15: ...Chapter 2 Safety information 9 ...
Страница 16: ... 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs 1 2 PERIGO 10 ThinkCentre Hardware Maintenance Manual ...
Страница 19: ...Chapter 2 Safety information 13 ...
Страница 20: ...1 2 14 ThinkCentre Hardware Maintenance Manual ...
Страница 21: ...Chapter 2 Safety information 15 ...
Страница 27: ...Chapter 2 Safety information 21 ...
Страница 31: ...Chapter 2 Safety information 25 ...
Страница 44: ...38 ThinkCentre Hardware Maintenance Manual ...
Страница 48: ...42 ThinkCentre Hardware Maintenance Manual ...
Страница 72: ...66 ThinkCentre Hardware Maintenance Manual ...
Страница 106: ...100 ThinkCentre Hardware Maintenance Manual ...
Страница 111: ......
Страница 112: ...Part Number 0A22817 Printed in USA 1P P N 0A22817 0A22817 ...