DCPMM contains spared internal cells to stand in for the failed ones. When the spared cells are exhausted
to 0%, there will be an error message, and it is advised to back up data, collect service log, and contact
Lenovo support.
There will also be a warning message when the percentage reaches 1% and a selectable percentage
(10% by default). When this message appears, it is advised to back up data and run DCPMM diagnostics
(see
https://sysmgt.lenovofiles.com/help/topic/LXPM/running_diagnostics.html
). To adjust the selectable
percentage that the warning message requires, go to
Intel Optane DCPMMs
➙
DCPMM Configuration
,
and input the percentage.
Alternatively, change the selectable percentage with the following command in OneCLI:
onecli.exe config set IntelOptaneDCPMM.PercentageRemainingThresholds 20
--imm USERID:[email protected]
Where
20
is the selectable percentage.
RAID configuration
Using a Redundant Array of Independent Disks (RAID) to store data remains one of the most common and
cost-efficient methods to increase server's storage performance, availability, and capacity.
RAID increases performance by allowing multiple drives to process I/O requests simultaneously. RAID can
also prevent data loss in case of a drive failure by reconstructing (or rebuilding) the missing data from the
failed drive using the data from the remaining drives.
RAID array (also known as RAID drive group) is a group of multiple physical drives that uses a certain
common method to distribute data across the drives. A virtual drive (also known as virtual disk or logical
drive) is a partition in the drive group that is made up of contiguous data segments on the drives. Virtual drive
is presented up to the host operating system as a physical disk that can be partitioned to create OS logical
drives or volumes.
An introduction to RAID is available at the following Lenovo Press website:
https://lenovopress.com/lp0578-lenovo-raid-introduction
Detailed information about RAID management tools and resources is available at the following Lenovo Press
website:
https://lenovopress.com/lp0579-lenovo-raid-management-tools-and-resources
Install the operating system
Several options are available to install an operating system on the server.
•
Lenovo XClarity Administrator
If you are managing your server using Lenovo XClarity Administrator, you can use it to deploy operating-
system images to up to 28 managed servers concurrently. For more information about using Lenovo
XClarity Administrator to deploy operating system images, see:
http://sysmgt.lenovofiles.com/help/topic/com.lenovo.lxca.doc/compute_node_image_deployment.html
•
Lenovo XClarity Provisioning Manager Lite
Lenovo XClarity Provisioning Manager Lite is used to install operating system of single server. You can
complete operating system installation by following the instructions in Lenovo XClarity Provisioning
Manager Lite OS Installation function.
75
Содержание ThinkAgile VX 4-Socket 4U Certified Node
Страница 6: ...iv User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Страница 10: ...viii User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Страница 69: ...Chapter 2 Server components 59 ...
Страница 76: ...66 User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Страница 96: ...86 User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Страница 252: ...242 User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Страница 276: ...266 User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Страница 284: ...274 User Guide for ThinkAgile VX7820 Appliance ThinkAgile VX 4 Socket 4U Certified Node ...
Страница 295: ......
Страница 296: ......