Table 44. Server management details
Item
Option
Description
BMC Self Test Status
N/A
-
BMC Device ID
N/A
-
BMC Device Revision
N/A
-
BMC Firmware Revision
N/A
-
IPMI Version
N/A
-
IPMI BMC Interface
N/A
-
BMC Support
Disabled/
Enabled
Enable/Disable interfaces to communicate with
BMC.
Wait For BMC
Disabled
/Enabled
Wait For BMC responses to specified time out. In
PILOTII, BMC starts at the same time when BIOS
starts during AC power on. It takes around 30
seconds to BMC interfaces.
FRB-2 Timer
Disabled/
Enabled
Enable or disable FRB-2 timer (POST timer).
FRB-2 Timer Timeout
N/A
Enter value between 1 to 30 minutes for FRB-2
timer expiration.
FRB-2 Timer Policy
Do Nothing
/Reset/Power Down/
Power Cycle
Configure how the system responds if the FRB-2
Timer expires. Not available if FRB-2 Timer is
disabled.
OS Watchdog Timer
Disabled
/Enabled
If enabled, start a BIOS timer which can only be
shut off by Intel Management Software after the OS
loads. Helps determine that the OS successfully
loaded or follows the OS Boot Watchdog Timer
policy.
OS Wtd Timer Timeout
N/A
Enter the value between 1 to 30 min for OS Boot
Watchdog Timer Expiration. Not available if OS
Boot Watchdog Timer is disabled.
OS Wtd Timer Policy
Do Nothing/
Reset
/Power Down/
Power Cycle
Configure how the system responds if the OS Boot
Watchdog Timer expires. Not available if OS Boot
Watchdog Timer is disabled.
Serial Mux
Disabled
/Enabled
Press Enter to enable or disable Serial Mux
configuration.
BMC Configured Power
Control Policy
N/A
-
Power Control Policy
Unspecified
/Power Restore/
Last Power State/Do not
PowerUp
Configure how the system responds if AC Power is
lost. Power Control Policy will take effect
immediately after it's saved.
System Event Log
N/A
Press Enter to change the SEL event log
configuration.
View FRU Information
N/A
Press Enter to view FRU information.
BMC Self Test Log
N/A
Log the report returned by BMC self test command.
BMC Network Configuration
N/A
Configure BMC network parameters.
View System Event Log
N/A
Press Enter to view the System Event Log Records.
132
HR650X V2 User Guide
Содержание HR650X V2
Страница 1: ...HR650X V2 User Guide Machine Types 7D4D ...
Страница 8: ......
Страница 14: ...6 HR650X V2 User Guide ...
Страница 30: ...22 HR650X V2 User Guide ...
Страница 122: ...114 HR650X V2 User Guide ...
Страница 152: ...144 HR650X V2 User Guide ...
Страница 176: ...168 HR650X V2 User Guide ...
Страница 182: ...174 HR650X V2 User Guide ...
Страница 186: ...178 HR650X V2 User Guide ...
Страница 190: ...182 HR650X V2 User Guide ...
Страница 191: ......
Страница 192: ......