Diagnostic Error Code
FRU/Action
170-199-XXX
Voltage Sensor(s) test failed, cause
unknown
1.
See “Undetermined problems” on page 66
2. Flash the system and re-test. See “Updating (flashing)
BIOS from a disc” on page 334
3. Replace component under function test
170-250-XXX 170-251-XXX
Voltage Sensor(s) Voltage
limit error
1.
AC/DC power adapter
2. System board
170-254-XXX
Voltage Sensor(s) Voltage Regulator
Module error
1.
Voltage Regulator Module (VRM)
2. Microprocessor
3. System board
175-000-XXX
Thermal Sensor(s) Test Passed
No action
175-0XX-XXX
Thermal Sensor(s) failure
1.
Flash system
2. System board
175-195-XXX
Thermal Sensor(s) Test aborted by user
Information only
Re-start the test, if necessary
175-196-XXX
Thermal Sensor(s) test halt, error threshold
exceeded
1.
Press F3 to review the log file
2. Re-start the test to reset the log file
175-197-XXX
Thermal Sensor(s) test warning
1.
Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 43
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
175-198-XXX
Thermal Sensor(s) test aborted
1.
If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test. See “Updating (flashing)
BIOS from a disc” on page 334
3. Go to “Undetermined problems” on page 66
175-199-XXX
Thermal Sensor(s) test failed, cause
unknown
1.
See “Undetermined problems” on page 66
2. Flash the system and re-test. See “Updating (flashing)
BIOS from a disc” on page 334
3. Replace component under function test
175-250-XXX 175-251-XXX
Thermal Sensor(s) limit error
1.
Check fans
2. Check AC/DC power adapter voltages
3. Microprocessor
4. System board
185-000-XXX
Asset Security Test Passed
No action
185-XXX-XXX
Asset Security failure
1.
Flash system
2. System board
185-278-XXX
Asset Security Chassis Intrusion
1.
Assure Asset Security Enabled
2. C2 Cover Switch
3. System board
201-000-XXX
System Memory Test Passed
No action
Chapter 7
.
Symptom-to-FRU index
61
Содержание 7359 - ThinkCentre M58 - 2 GB RAM
Страница 2: ......
Страница 15: ...Chapter 2 Safety information 9 ...
Страница 16: ... 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs 1 2 PERIGO 10 ThinkCentre Hardware Maintenance Manual ...
Страница 19: ...Chapter 2 Safety information 13 ...
Страница 20: ...1 2 14 ThinkCentre Hardware Maintenance Manual ...
Страница 21: ...1 2 Chapter 2 Safety information 15 ...
Страница 26: ...1 2 20 ThinkCentre Hardware Maintenance Manual ...
Страница 30: ...24 ThinkCentre Hardware Maintenance Manual ...
Страница 34: ...28 ThinkCentre Hardware Maintenance Manual ...
Страница 38: ...32 ThinkCentre Hardware Maintenance Manual ...
Страница 42: ...36 ThinkCentre Hardware Maintenance Manual ...
Страница 48: ...42 ThinkCentre Hardware Maintenance Manual ...
Страница 52: ...46 ThinkCentre Hardware Maintenance Manual ...
Страница 338: ...332 ThinkCentre Hardware Maintenance Manual ...
Страница 342: ...336 ThinkCentre Hardware Maintenance Manual ...
Страница 346: ...340 ThinkCentre Hardware Maintenance Manual ...
Страница 347: ......
Страница 348: ...Part Number 53Y6832 Printed in USA 1P P N 53Y6832 53Y6832 ...