Installing a simple-swap hard disk drive
This procedure applies only to server models that have simple-swap SATA hard disk
drives. See the
User Guide
for information about the installation sequence and
other important information.
Attention:
Simple-swap hard disk drives are not hot-swappable. Disconnect all
power from the server you remove or install a simple-swap hard disk drive.
To install a simple-swap hard disk drive, complete the following steps:
1. Touch the static-protective package that contains the drive to any unpainted
metal surface on the server; then, remove the drive from the package and place
it on a static-protective surface.
2. Align the drive assembly with the guide rails in the bay.
3. Pull the loops of the drive assembly toward each other; then, carefully slide the
drive assembly into the drive bay until it stops, and release the loops.
Note:
Do not release the loops on the drive assembly until it is completely
seated.
4. Install the lower bezel (see “Installing the lower bezel” on page 65).
5. Lock the side cover.
6. Reconnect the external cables and power cords; then, turn on the attached
devices and turn on the server.
80
ThinkServer TS100 Types 6431, 6432, 6433, and 6434: Hardware Maintenance Manual
Содержание 6431
Страница 1: ...ThinkServer TS100 Types 6431 6432 6433 and 6434 Hardware Maintenance Manual ...
Страница 2: ......
Страница 3: ...ThinkServer TS100 Types 6431 6432 6433 and 6434 Hardware Maintenance Manual ...
Страница 34: ...16 ThinkServer TS100 Types 6431 6432 6433 and 6434 Hardware Maintenance Manual ...
Страница 54: ...36 ThinkServer TS100 Types 6431 6432 6433 and 6434 Hardware Maintenance Manual ...
Страница 268: ...250 ThinkServer TS100 Types 6431 6432 6433 and 6434 Hardware Maintenance Manual ...
Страница 283: ......
Страница 284: ...Part Number 46U0853 Printed in USA 1P P N 46U0853 ...