background image

Committed Repair Service

Committed Repair Services enhances the level of Warranty Service Upgrade or Post

Warranty/Maintenance Service offering associated with the selected systems. Offerings vary and

are available in select countries.

Priority handling to meet defined time frames to restore the failing machine to good working

condition

Committed repair service levels are measured within the following coverage hours:

24x7x6: Service performed 24 hours per day, 7 days per week, within 6 hours

24x7x8: Service performed 24 hours per day, 7 days per week, within 8 hours

24x7x24: Service performed 24 hours per day, 7 days per week, within 24 hours

Hard Disk Drive Retention

Lenovo’s Hard Disk Drive Retention (HDDR) service is a multi-drive hard drive retention offering that

ensures your data is always under your control, regardless of the number of hard drives that are

installed in your Lenovo server. In the unlikely event of a hard drive failure, you retain possession of

your hard drive while Lenovo replaces the failed drive part. Your data stays safely on your premises,

in your hands. The Hard Drive Retention service can be purchased in convenient bundles with our

warranty upgrades and extensions.

Microcode Support

Keeping microcode current helps prevent hardware failures and security exposure. There are two

levels of service: analysis of the installed base and analysis and update where required. Offerings

vary by country and can be bundled with other warranty upgrades and extensions.

Remote Technical Support Services (RTS)

RTS provides comprehensive technical call center support for covered servers, storage, operating

systems, and applications. Providing a single source for support of hardware and software issues,

RTS can reduce problem resolution time, decreasing the cost to address technical problems and

increasing uptime. Offerings are available for Windows, Linux, IBM Systems Director, VMware,

Microsoft business applications, and Lenovo System x storage devices, and IBM OEM storage

devices.

Regulatory compliance

Lenovo System x3850 X6 (6241)

49

Содержание 6241

Страница 1: ...The x3850 X6 supports up to four Intel Xeon E7 high performance processors and up to 12 TB of memory Suggested use mission critical scalable databases business analytics virtualization enterprise applications and cloud applications The following figure shows the Lenovo System x3850 X6 Figure 1 Lenovo System x3850 X6 machine type 6241 Did you know The x3850 X6 server employs a lid less design where...

Страница 2: ...nnect links at up to 9 6 GTps Supports DDR4 memory at speeds up to 1866 MHz or DDR3 memory at speeds up to 1600 MHz Supports up to 96 DIMM sockets with 24 DIMMs per processor Intelligent and adaptive system performance with Intel Turbo Boost Technology 2 0 allows processor cores to run at maximum speeds during peak workloads by temporarily going beyond processor thermal design power TDP Intel Hype...

Страница 3: ...on the floor Resilient platform The server provides many features to simplify serviceability and increase system uptime Upward Integration Modules for standard hypervisors enable the creation and management of policies to maintain high availability of virtual machines and concurrent updating of the system firmware with no impact on application performance or availability Advanced Processor Recover...

Страница 4: ... case of failures to minimize downtime Includes a special Mezzanine LOM ML2 adapter slot with support for adapters with either two 10 Gb ports or four 1 Gb ports Supports direct connectivity to the IMM2 service processor for out of band systems management Integrated industry standard Unified Extensible Firmware Interface UEFI enables improved setup configuration and updates and simplifies error ha...

Страница 5: ...he following figure shows the front of the x3850 X6 server Figure 2 Front view of the Lenovo System x3850 X6 The following figure shows the rear of the x3850 X6 server Figure 3 Rear view of the Lenovo System x3850 X6 Lenovo System x3850 X6 6241 5 ...

Страница 6: ... memory and Compute Books with TruDDR4 memory cannot be mixed in the same system Memory maximums Models with TruDDR4 Compute Books With RDIMMs Up to 3 TB with 96x 32 GB RDIMMs and four processors With LRDIMMs Up to 6 TB with 96x 64 GB LRDIMMs and four processors With 3DS RDIMMs Up to 12 TB with 96x 128 GB RDIMMs and four processors Models with DDR3 Compute Books With RDIMMs Up to 1 5 TB with 96x 1...

Страница 7: ...ooks Video Matrox G200eR2 with 16 MB memory that is integrated into the IMM2 Maximum resolution is 1600 x 1200 at 75 Hz with 16 M colors Security features Power on password admin password and an integrated Trusted Platform Module supporting TPM 2 0 and TPM 1 2 Systems management UEFI Integrated Management Module II IMM2 with remote presence feature Predictive Failure Analysis Light Path Diagnostic...

Страница 8: ...4820 v4 10C 2 0GHz 25M 115W 4x 16GB 1866MHz 1x M5210 4x 2 5 8 Open bay 4x 1 GbE 6 std 12 max 2x 900W HS 4 6241 E2U 2x E7 4850 v4 16C 2 1GHz 40M 115W 4x 16GB 1866MHz 1x M5210 4x 2 5 8 Open bay 4x 1 GbE 6 std 12 max 2x 900W HS 4 6241 E3U 2x E7 8890 v4 24C 2 2GHz 60M 165W 4x 16GB 1866MHz 1x M5210 4x 2 5 8 Open bay 4x 1 GbE 6 std 12 max 2x 900W HS 4 x in the Machine Type Model MTM represents a country...

Страница 9: ...W 512 GB 32x 16GB DDR4 RDIMM 1x M5210 upgrades 8x 2 5 bays 6x 1 2 TB SAS HDD 2x 400 GB S3710 SSD 1x 4x1GbE ML2 2x Mellanox 10Gb 12 std 12 max 4x 1400W HS 4 6241 8Fx 4x E7 8880 v4 22C 2 2GHz 55M 150W 1024 GB 32x 32GB DDR4 RDIMM 1x M5210 upgrades 1x M5225 upgrades 8x 2 5 bays 6x 1 2 TB SAS HDD 2x 400 GB S3710 SSD 1x 4x1GbE ML2 2x Mellanox 10Gb 12 std 12 max 4x 1400W HS 4 SAP HANA models with E7 v4 p...

Страница 10: ...DIMM 1x M5210 upgrades 8x 2 5 HS 6x 1 2 TB SAS HDD 2x 400 GB S3700 SSD 1x 4x1GbE ML2 2x Mellanox 10Gb 6 std 12 max 4x 1400W HS 4 Model Intel Xeon Compute Book Memory RAID Drive bays Drives Ethernet I O slots Power supplies See the list of specific components below Each of these HANA models include the following components ServeRAID M5210 controller 46C9110 with 2GB cache upgrade with flash backup ...

Страница 11: ...uire minimum firmware levels Consult the documentation that is included with the Compute Books Compute books with E7 v4 processors do not support DDR3 memory If you upgrade from E7 v3 processors with DDR4 to E7 v4 processors you can transfer the 2133 MHz DDR4 memory DIMMs to the new compute books If you also want to add additional memory to the E7 v4 compute book it is supported to use either 2133...

Страница 12: ... of the RPQ a service engineer comes onsite with the new mechanical chassis and performs the field upgrade by transferring all components to the new chassis This method also requires the x3850 X6 compute books be the same E7 8800 series processors as ordered for the RPQ however in this scenario the server maintain the original serial number Note Use of E7 4800 processors Intel Xeon E7 4800 v2 v3 v...

Страница 13: ...ed to use configure to order or order the server using Special Bid to create a server configuration with E7 8800 processors Serial number swap The RPQ upgrade process also involves transferring the x3850 X6 serial number to the x3950 X6 chassis This transfer makes the upgrade simpler from an asset or depreciation management point of view This transfer also means that the old 4U chassis will be ret...

Страница 14: ...ssors in Compute Books with TruDDR4 support E7 8800 v3 processors in Compute Books with TruDDR4 support Each option includes the processor installed in a Compute Book Compute Books with one of the E7 4800 family of processors are supported only in a four socket x3850 X6 server and cannot be used in an x3950 X6 server All Compute Books installed in a server must be identical The table also shows th...

Страница 15: ...4 24C 2 4GHz 60M 165W 60 MB 9 6 GHz TruDDR4 1866 MHz 1600 MHz Y Y Intel Xeon E7 4800 v3 processors with support for DDR3 memory not supported in the x3950 X6 00ML902 AS7T AS8H X6 DDR3 Compute Book E7 4809 v3 8C 2 0GHz 115W 20 MB 6 4 GHz DDR3 1333 MHz 1333 MHz Y N D4x 00ML906 AS7U AS8J X6 DDR3 Compute Book E7 4820 v3 10C 1 9GHz 115W 25 MB 6 4 GHz DDR3 1333 MHz 1333 MHz Y N F1x 00ML910 AS7V AS8K X6 ...

Страница 16: ... AS8Z X6 DDR4 Compute Book E7 8870 v3 18C 2 1GHz 140W 45 MB 9 6 GHz TruDDR4 1866 MHz 1600 MHz Y Y 00ML978 AS8A AS90 X6 DDR4 Compute Book E7 8880 v3 18C 2 3GHz 150W 45 MB 9 6 GHz TruDDR4 1866 MHz 1866 MHz Y Y HANA models 00ML986 AS8C AS92 X6 DDR4 Compute Book E7 8880L v3 18C 2 0GHz 115 45 MB 9 6 GHz TruDDR4 1866 MHz 1600 MHz Y Y 00ML982 AS8B AS91 X6 DDR4 Compute Book E7 8890 v3 18C 2 5GHz 165W 45 M...

Страница 17: ... up to 96 DIMMs when all processors are installed 24 DIMMs per processor Each processor has four memory channels that are implemented using Scalable Memory Interface generation 2 SMI2 chips and the server implements three DIMMs per channel The processor and the corresponding memory DIMM slots are on the Compute Book The following table lists the memory options that are available for x3850 X6 Table...

Страница 18: ... channel is six with RDIMMs 12 with LRDIMMs or 24 with 3DS RDIMMs In RAS lockstep mode DIMMs must be installed in a pair The maximum quantity of DIMMs that can be installed in the server depends on the number of processors DIMM type rank and operating voltage as shown in the Maximum qty supported row in the following table All DIMMs in the server operate at the same speed which is determined as th...

Страница 19: ...ity supported is shown for all processors that are installed This speed is above the Intel standard and is achieved only when Lenovo TruDDR4 memory is used Table 8 Maximum memory speeds 2133 MHz TruDDR4 memory Specification TruDDR4 RDIMMs TruDDR4 LRDIMMs Rank Single rank Dual rank Quad rank Part numbers 46W0788 8 GB 46W0796 16 GB 95Y4808 32 GB 95Y4812 64 GB Rated speed 2133 MHz 2133 MHz 2133 MHz R...

Страница 20: ...channel 1333 MHz 1600 MHz 1333 MHz 1600 MHz 1333 MHz 1600 MHz 1333 MHz 1333 MHz 2 DIMMs per channel 1333 MHz 1600 MHz 1333 MHz 1600 MHz 1333 MHz 1600 MHz 1333 MHz 1333 MHz 3 DIMMs per channel 1066 MHz 1333 MHz 1066 MHz 1333 MHz 1333 MHz 1333 MHz 1333 MHz 1333 MHz Maximum quantity supported is shown for all processors that are installed The following memory protection technologies are supported ECC...

Страница 21: ...rive bays 8x 2 5 inch hot swap drive bays 4x 2 5 inch hot swap drive bays 8x 1 8 inch hot swap SSD bays 8x 1 8 inch hot swap SSD bays 16x 1 8 inch hot swap SSD bays 4x 2 5 inch PCIe NVMe SSDs 2x 2 5 inch PCIe NVMe SSDs 8x 1 8 inch HDD hot swap drives 2x 2 5 inch PCIe NVMe SSDs 4x 2 5 inch HDD hot swap drives The following figure shows these configurations Figure 5 Internal drive configurations Bac...

Страница 22: ...e Gen3 SSD Backplane 1 Withdrawn from marketing The backplanes are connected to one or two RAID controllers or HBAs depending on the number and type of backplane that is installed The adapters are installed in PCIe slots in the Storage Book as shown in the following figure Figure 6 Storage Book The following table shows the backplanes that are required per Storage Book and the number of controller...

Страница 23: ...SAS HDD Backplane 44X4106 1 16x 1 8 inch hot swap SSD bays 2x 8x 1 8 HS 12Gb SAS HDD Backplane 44X4106 2 4x 2 5 inch NVMe 1x 4x 2 5 inch NVMe PCIe SSD Backplane 44X4108 1 or 2 2x 2 5 inch NVMe 4x 2 5 inch HDD SSD 1x 4x 2 5 inch NVMe PCIe SSD Backplane 44X4108 1x 4x 2 5 HS 12Gb SAS HDD Backplane 44X4104 2 2x 2 5 inch NVMe 8x 1 8 inch SSD 1x 4x 2 5 inch NVMe PCIe SSD Backplane 44X4108 1x 8x 1 8 HS 1...

Страница 24: ...upgrades for the M5210 47C8656 A3Z0 ServeRAID M5200 Series 1GB Cache RAID 5 Upgrade 2 47C8660 A3Z1 ServeRAID M5200 Series 1GB Flash RAID 5 Upgrade 2 47C8664 A3Z2 ServeRAID M5200 Series 2GB Flash RAID 5 Upgrade 2 47C8668 A3Z3 ServeRAID M5200 Series 4GB Flash RAID 5 Upgrade 2 Features on Demand upgrades for the M5210 47C8708 A3Z6 ServeRAID M5200 Series Zero Cache RAID 5 Upgrade 1 47C8706 A3Z5 ServeR...

Страница 25: ... 47C8660 2 GB flash backup 47C8664 4 GB flash backup 47C8668 None None CacheVault cache protection Optional None None Performance Accelerator FastPath Optional 47C8710 No No SSD Caching CacheCade Pro 2 0 Optional 47C8712 No No SED support SafeStore Yes with RAID 5 FoD upgrade or any cache upgrade No No For more information see the list of Lenovo Press Product Guides in the RAID adapters category h...

Страница 26: ... and solid state drive options for the internal disk storage of the server Table 14 2 5 inch hot swap 12 Gb SAS HDDs Table 15 2 5 inch hot swap 6 Gb SAS SATA HDDs Table 16 2 5 inch hot swap 12 Gb SAS SSDs Table 17 2 5 inch hot swap 6 Gb SAS SATA SSDs Table 18 2 5 inch NVMe SSDs Lenovo System x3850 X6 6241 26 ...

Страница 27: ...3HS 512e HDD 8 2 5 inch hot swap HDDs 12 Gb NL SAS 00NA491 AT7Z 1TB 7 2K 12Gbps NL SAS 2 5 G3HS HDD 8 00NA496 AT80 2TB 7 2K 12Gbps NL SAS 2 5 G3HS 512e HDD 8 2 5 inch hot swap SED HDDs 12 Gb SAS 10K 00WG705 AT8D 300GB 10K 12Gbps SAS 2 5 G3HS SED 8 00WG710 AT8E 600GB 10K 12Gbps SAS 2 5 G3HS SED 8 00WG715 AT8F 900GB 10K 12Gbps SAS 2 5 G3HS SED 8 00WG720 AT8G 1 2TB 10K 12Gbps SAS 2 5 G3HS SED 8 Table...

Страница 28: ...Performance 12G SAS G3HS 2 5 SSD 8 01GV721 AVL2 1 6TB Enterprise Performance 12G SAS G3HS 2 5 SSD 8 00FN379 AS7C 200GB 12G SAS 2 5 MLC G3HS Enterprise SSD 8 00FN389 AS7E 400GB 12G SAS 2 5 MLC G3HS Enterprise SSD 8 00FN409 AS7J 1 6TB 12G SAS 2 5 MLC G3HS Enterprise SSD 8 2 5 inch hot swap SSDs 12 Gb SAS Enterprise Mainstream 3 5 DWPD 01GV761 AWEY PM1635a 400GB Enterprise Mainstream 12Gb SAS G3HS 2 ...

Страница 29: ...2 5 SSD 8 7SD7A05730 B0ZA Intel S4500 960GB Enterprise Entry SATA G3HS 2 5 SSD 8 4XB7A08493 B0ZB Intel S4500 1 92TB Enterprise Entry SATA G3HS 2 5 SSD 8 4XB7A08494 B0ZC Intel S4500 3 84TB Enterprise Entry SATA G3HS 2 5 SSD 8 01KR496 AXGL 5100 480GB Enterprise Entry SATA G3HS 2 5 SSD 8 01KR501 AXGM 5100 960GB Enterprise Entry SATA G3HS 2 5 SSD 8 01KR506 AXGN 5100 1 92TB Enterprise Entry SATA G3HS 2...

Страница 30: ...1 92TB NVMe 2 5 Enterprise Mainstream PCIe SSD 4 00YK284 AVP1 960GB NVMe 2 5 Enterprise Mainstream PCIe SSD 4 2 5 inch SSDs NVMe Enterprise Entry 3 DWPD 7SD7A05774 B11F Intel P4500 1 0TB NVMe 2 5 Enterprise Entry PCIe SSD 4 7SD7A05773 B11G Intel P4500 2 0TB NVMe 2 5 Enterprise Entry PCIe SSD 4 4XB7A08539 B1JK Intel P4500 4 0TB NVMe 2 5 Enterprise Entry PCIe SSD 4 01GR660 AVPN PM963 1 92TB NVMe 2 5...

Страница 31: ... full height up to 75 W of power One mezzanine LOM 2 ML2 slot for network adapters with the new ML2 form factor PCIe 3 0 x8 Two optional I O Books each with three slots all full height Optional I O Books are enabled for hot swap The following figure shows the Primary I O Book with the air baffle raised to show the internals Figure 8 Primary I O Book Optional I O Books can be either of Half length ...

Страница 32: ...0 T2 2xGbE BaseT Adapter for System x 00AG520 A56M Intel I350 T4 4xGbE BaseT Adapter for System x Hot swap is only supported when the adapter is in pNIC mode Hot swap is not supported in either vNIC mode Virtual Fabric mode or Switch Independent mode Optional I O books The usage of these Optional I O Books requires all four processors to be installed The following table shows the ordering informat...

Страница 33: ...y power connectors With the use of these connectors and the supplied power cords the I O book supports one double wide adapter up to 300 W The auxiliary power connectors are as follows One 2x4 power connector which supplies up to 150 W of additional power to the adapter One 2x3 power connector which supplies up to 75 W of additional power to the adapter The combined power consumption of all the ad...

Страница 34: ...e other x16 slot Figure 11 Full length I O Book The Half length I O Book installs flush with the Primary I O Book at the rear of the server The Full length I O Book when installed adds a 99 mm 3 9 in mechanical extension to the base length dimension of the chassis The following figure shows a Full length I O Book and a Half length I O Book installed in the server Figure 12 I O Books that are insta...

Страница 35: ...2 Quad Port GbE Adapter I350 AM4 based The Broadcom NetXtreme II ML2 Dual Port 10GbE SFP Adapter has the following specifications Dual port 10 Gb Ethernet connectivity Broadcom BCM57810S ASIC SFP ports supporting fiber optic and direct attach copper DAC cables For more information about this adapter see the Product Guide http lenovopress com tips1027 The Intel I350 T4 ML2 Quad Port GbE Adapter has...

Страница 36: ... 10 00JY940 ATRH Intel X710 DA2 ML2 2x10GbE SFP Adapter 1 10 94Y5200 AS74 Intel X710 ML2 4x10GbE SFP Adapter 1 10 Gigabit Ethernet 00D1998 A40R Intel I350 T4 ML2 Quad Port GbE Adapter 1 10 InfiniBand 00FP650 A5RK Mellanox ConnectX 3 Pro ML2 2x40GbE FDR VPI Adapter 1 10 Not supported in servers with E7 v2 compute books The server also supports various other Ethernet InfiniBand and Omni Path network...

Страница 37: ...850 ATRY Intel X550 T1 Single Port 10GBase T Adapter 9 1 9 00MM860 ATPX Intel X550 T2 Dual Port 10GBase T Adapter 9 1 9 01DA900 AU2Y Intel X710 DA2 2x10GbE SFP Adapter 9 1 9 00D9690 A3PM Mellanox ConnectX 3 10 GbE Adapter 9 1 9 Gigabit Ethernet 90Y9370 A2V4 Broadcom NetXtreme I Dual Port GbE Adapter 9 1 9 90Y9352 A2V3 Broadcom NetXtreme I Quad Port GbE Adapter 9 1 9 49Y4230 5767 Intel Ethernet Dua...

Страница 38: ...ATZB QLogic 16Gb Enhanced Gen5 FC Single port HBA 9 1 9 01CV760 ATZC QLogic 16Gb Enhanced Gen5 FC Dual port HBA 9 1 9 Fibre Channel 16 Gb 81Y1655 A2W5 Emulex 16Gb FC Single port HBA 9 1 9 81Y1662 A2W6 Emulex 16Gb FC Dual port HBA 9 1 9 00Y3337 A3KW QLogic 16Gb FC Single port HBA 9 1 9 00Y3341 A3KX QLogic 16Gb FC Dual port HBA 9 1 9 Fibre Channel 8 Gb 42D0485 3580 Emulex 8 Gb FC Single port HBA 9 1...

Страница 39: ... ServeRAID M5120 SAS SATA Controller 3 7 8 9 Features on Demand upgrades for the M5225 1 per server 47C8706 A3Z5 ServeRAID M5200 Series RAID 6 Upgrade for Systems FoD 1 47C8710 A3Z7 ServeRAID M5200 Series Performance Accelerator for Systems FoD 1 47C8712 A3Z8 ServeRAID M5200 Series SSD Caching Enabler for Systems FoD 1 Hardware upgrades for the M5120 1 per adapter mutually exclusive 81Y4487 A1J4 S...

Страница 40: ...Maximum number of devices 1024 1024 1024 240 240 RAID levels None None None 0 1 10 Optional 5 50 and 6 60 0 1 10 5 50 Optional 6 60 47C8706 JBOD mode Yes Yes Yes No No Cache None None None Optional 512MB 1GB or 2GB 2 GB included CacheVault cache protection None None None Flash with cache upgrades Flash included FastPath None None None Optional 90Y4273 Optional 47C8710 CacheCade Pro 2 0 None None N...

Страница 41: ... processors and graphics processing units GPUs that are listed in the following table Each is installed in a Full length I O Book No other adapter can be installed in the Full length I O Book The Full length I O Book includes the necessary auxiliary power cables The maximum supported column indicates which slots each adapter is supported in For slot locations see the Slot locations section Notes T...

Страница 42: ...o 1400 W options 44X4152 for low altitude and 44X4150 for high altitude as you will nullify the high altitude capabilities of 44X4150 You cannot mix the AC power supplies with the DC power supply Use the Power Configurator to determine exactly what power your server needs https support lenovo com documents LNVO PWRCONF Integrated virtualization The server supports VMware ESXi that is installed on ...

Страница 43: ...ser The remote presence provides the following functions Remotely viewing video with graphics resolutions up to 1600 x 1200 at 75 Hz with up to 23 bits per pixel colors regardless of the system state Remotely accessing the server by using the keyboard and mouse from a remote client Mapping the CD or DVD drive diskette drive and USB flash drive on a remote client and mapping ISO and diskette image ...

Страница 44: ...lenovopress com osig The following operating systems are supported with E7 v4 compute books Microsoft Windows Server 2012 Microsoft Windows Server 2012 R2 Microsoft Windows Server 2016 Microsoft Windows Server version 1709 Red Hat Enterprise Linux 6 7 x64 Red Hat Enterprise Linux 6 8 x64 Red Hat Enterprise Linux 7 2 Red Hat Enterprise Linux 7 3 Red Hat Enterprise Linux 7 4 Red Hat Enterprise Linux...

Страница 45: ... Linux Enterprise Server 12 SUSE Linux Enterprise Server 12 SP1 SUSE Linux Enterprise Server 12 SP2 SUSE Linux Enterprise Server 12 SP3 SUSE Linux Enterprise Server 12 Xen SUSE Linux Enterprise Server 12 Xen SP1 SUSE Linux Enterprise Server 12 Xen SP2 SUSE Linux Enterprise Server 12 Xen SP3 VMware ESXi 5 5 U2 VMware ESXi 5 5 U3 VMware ESXi 6 0 VMware ESXi 6 0 U1 VMware ESXi 6 0 U2 VMware ESXi 6 0 ...

Страница 46: ...e Server 12 SP2 SUSE Linux Enterprise Server 12 Xen SUSE Linux Enterprise Server 12 Xen SP1 SUSE Linux Enterprise Server 12 Xen SP2 VMware ESXi 5 1 U2 VMware ESXi 5 1 U3 VMware ESXi 5 5 VMware ESXi 5 5 U1 VMware ESXi 5 5 U2 VMware ESXi 5 5 U3 VMware ESXi 6 0 VMware ESXi 6 0 U1 VMware ESXi 6 0 U2 Physical and environmental specifications Lenovo System x3850 X6 6241 46 ...

Страница 47: ... 24 C Server off 8 85 maximum dew point 27 C Electrical Models with 1400 W AC power supplies 100 127 nominal V AC 50 Hz or 60 Hz 10 A 900 W DC output 200 240 nominal V AC 50 Hz or 60 Hz 8 A 1400 W DC output Input kilovolt amperes kVA approximately Minimum configuration 0 16 kVA Maximum configuration 3 2 kVA Models with 900 W AC power supplies 100 127 nominal V AC 50 Hz or 60 Hz 10 7 A 200 240 nomi...

Страница 48: ...around the clock every day including Lenovo holidays 24x7x4 hour A service technician is scheduled to arrive at the client s location within four hours after remote problem determination is completed Lenovo provides service around the clock every day including Lenovo holidays 9x5x4 hour A service technician is scheduled to arrive at the client s location within four business hours after remote pro...

Страница 49: ...a hard drive failure you retain possession of your hard drive while Lenovo replaces the failed drive part Your data stays safely on your premises in your hands The Hard Drive Retention service can be purchased in convenient bundles with our warranty upgrades and extensions Microcode Support Keeping microcode current helps prevent hardware failures and security exposure There are two levels of serv...

Страница 50: ...land AS NZS CISPR 22 Class A IEC 60950 1 CB Certificate and CB Test Report China CCC GB4943 GB9254 Class A GB17625 1 Taiwan BSMI CNS13438 Class A CNS14336 1 Korea KN22 Class A KN24 Russia GOST ME01 IEC 60950 1 GOST R 51318 22 GOST R 51318 24 GOST R 51317 3 2 and GOST R 51317 3 3 IEC 60950 1 CB Certificate and CB Test Report CE Mark EN55022 Class A EN60950 1 EN55024 EN61000 3 2 and EN61000 3 3 CISP...

Страница 51: ...ion Dual SAS IO Module Rail Kit 9x5 NBD For details about supported drives and cables for the Lenovo Storage E1012 and E1024 see the Lenovo Press Product Guide http lenovopress com lp0043 The following table lists the standard models of the 12 Gbps SAS external drive enclosures offered by Lenovo that can be used with the server for storage expansion Table 32 D1212 and D1224 standard models Part nu...

Страница 52: ...is Dual 3 port ESMs 12x 8TB 3 5 HDDs 4x 0 5m SAS cables Brazil and Latin America SFF models 4587E6U D1224 SFF Chassis Dual 3 port ESMs 9x 1 2TB 10K HDDs 4x 0 5m SAS cables 4587E2U D1224 SFF Chassis Dual 3 port ESMs 9x 1 2TB 10K HDDs 2x 400GB SSDs 4x 0 5m SAS cables 4587E4U D1224 SFF Chassis Dual 3 port ESMs 9x 1 2TB 10K HDDs 4x 400GB SSDs 4x 0 5m SAS cables 4587E5U D1224 SFF Chassis Dual 3 port ES...

Страница 53: ...4599A21 Lenovo ThinkSystem DS2200 SFF SAS Dual Controller Unit US English documentation 4599A2C Lenovo ThinkSystem DS2200 SFF SAS Dual Controller Unit Simplified Chinese documentation 4599A2J Lenovo ThinkSystem DS2200 SFF SAS Dual Controller Unit Japanese documentation 4617A41 Lenovo ThinkSystem DS4200 LFF SAS Dual Controller Unit US English documentation 4617A4C Lenovo ThinkSystem DS4200 LFF SAS ...

Страница 54: ...ller 6535C3D Lenovo Storage V3700 V2 XP LFF Control Enclosure 6535EC3 Lenovo Storage V3700 V2 XP LFF Control Enclosure TopSeller 6535C4D Lenovo Storage V3700 V2 XP SFF Control Enclosure 6535EC4 Lenovo Storage V3700 V2 XP SFF Control Enclosure TopSeller 6536C12 Lenovo Storage V5030 LFF Control Enclosure 3Yr S S 6536C32 Lenovo Storage V5030 LFF Control Enclosure 5Yr S S 6536C22 Lenovo Storage V5030 ...

Страница 55: ...DX8200D Storage Virtualization High 64TB 4yr SW S S 51353Wx Lenovo Storage DX8200D Storage Virtualization High 64TB 5yr SW S S 5135D3x Lenovo Storage DX8200D ServerSAN Entry 8TB 3yr SW S S 5135N3x Lenovo Storage DX8200D ServerSAN Entry 8TB 4yr SW S S 51354Wx Lenovo Storage DX8200D ServerSAN Entry 8TB 5yr SW S S 5135F3x Lenovo Storage DX8200D ServerSAN Mid 16TB 3yr SW S S 5135P3x Lenovo Storage DX8...

Страница 56: ... Autoloader w LTO7 HH SAS External tape backup libraries 61732UL IBM TS3100 Tape Library Model L2U 61734UL IBM TS3200 Tape Library Model L4U Fibre Channel backup drives for TS3100 and TS3200 Tape Libraries 00NA107 6173 LTO Ultrium 5 Fibre Channel Drive 00NA113 6173 LTO Ultrium 5 Half High Fibre Drive Sled 00NA115 6173 LTO Ultrium 6 Fibre Channel Drive 00NA119 6173 LTO Ultrium 6 Half High Fibre Dri...

Страница 57: ...kSwitch G8264CS Rear to Front 7159CRW Lenovo RackSwitch G8272 Rear to Front 7159GR6 Lenovo RackSwitch G8296 Rear to Front 25 Gb Ethernet switches 7159E1X Lenovo ThinkSystem NE2572 RackSwitch Rear to Front 40 Gb Ethernet switches 7159BRX Lenovo RackSwitch G8332 Rear to Front 100 Gb Ethernet switches 7159D1X Lenovo ThinkSystem NE10032 RackSwitch Rear to Front For more information see the list of Pro...

Страница 58: ...rprise SW 1 PS Rail Kit 3873AR5 Lenovo B6505 12 ports activated w 16Gb SWL SFPs 1 PS Rail Kit 3873BR3 Lenovo B6510 24 ports activated w 16Gb SWL SFPs 2 PS Rail Kit 32 Gb FC 6559D3Y Lenovo ThinkSystem DB610S 8 ports activated 1 PS Rail Kit 6415G11 Lenovo ThinkSystem DB620S 24 Ports Activated 24x 32Gb SWL SFPs 2 PS Rail Kit 6415G2A Lenovo ThinkSystem DB620S 48 Ports Activated 48x 32Gb SWL SFPs 2 PS ...

Страница 59: ...Part number Description 0U Basic PDUs 00YJ776 0U 36 C13 6 C19 24A 200 240V 1 Phase PDU with NEMA L6 30P line cord 00YJ777 0U 36 C13 6 C19 32A 200 240V 1 Phase PDU with IEC60309 332P6 line cord 00YJ778 0U 21 C13 12 C19 32A 200 240V 346 415V 3 Phase PDU with IEC60309 532P6 line cord 00YJ779 0U 21 C13 12 C19 48A 200 240V 3 Phase PDU with IEC60309 460P9 line cord Switched and Monitored PDUs 00YJ780 0U...

Страница 60: ... cord 39Y8934 DPI 32amp 250V Front end PDU with IEC 309 2P Gnd line cord 39Y8940 DPI 60amp 250V Front end PDU with IEC 309 2P Gnd line cord 39Y8935 DPI 63amp 250V Front end PDU with IEC 309 2P Gnd line cord NEMA PDUs 6x NEMA 5 15R outlets 39Y8905 DPI 100 127V PDU with Fixed NEMA L5 15P line cord Line cords for PDUs that ship without a line cord 40K9611 DPI 32a Line Cord IEC 309 3P N G 40K9612 DPI ...

Страница 61: ... 9363 4CX PureFlex System 42U Rack Yes 10 9363 4DX PureFlex System 42U Expansion Rack Yes 10 9363 4PX 42U 1100mm Dynamic Rack Yes 10 9363 4EX 42U 1100mm Dynamic Expansion Rack Yes 10 1410 2RX Intelligent Cluster 25U Rack Family No Not applicable 1410 4RX Intelligent Cluster 42U Rack Family Yes 10 1410 PRA Intelligent Cluster 42U 1200mm Deep Rack Family Yes 10 1410 PRB Intelligent Cluster 42U 1100m...

Страница 62: ...oard w Int Pointing Device USB Portuguese 163 RoHS v2 46W6732 Keyboard w Int Pointing Device USB Russian 441 RoHS v2 46W6733 Keyboard w Int Pointing Device USB Slovak 245 RoHS v2 46W6734 Keyboard w Int Pointing Device USB Spanish 172 RoHS v2 46W6735 Keyboard w Int Pointing Device USB Swed Finn 153 RoHS v2 46W6736 Keyboard w Int Pointing Device USB Swiss F G 150 RoHS v2 46W6737 Keyboard w Int Point...

Страница 63: ...flexible policies support our goal of providing customers with a positive experience We finance your entire solution Unlike others we allow you to bundle everything you need from hardware and software to service contracts installation costs training fees and sales tax If you decide weeks or months later to add to your solution we can consolidate everything into a single invoice Our Premier Client ...

Страница 64: ...tp systemx lenovofiles com help index jsp topic 2Fcom lenovo sysx 6241 doc 2Fprintable_doc html Lenovo System x3950 X6 Product Guide http lenovopress com tips1251 ServerProven hardware compatibility page for the x3850 X6 and x3950 X6 http www lenovo com us en serverproven xseries 6241E7xxxxV4 shtml xREF System x Reference http lenovopress com xref Support Portal for the x3850 X6 http support lenov...

Страница 65: ...ument are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo product specifications or warranties Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third par...

Страница 66: ...erveRAID ServerGuide ServerProven System x ThinkServer ThinkSystem TopSeller TruDDR4 UltraNav eXFlash vNIC The following terms are trademarks of other companies Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries Linux is a trademark of Linus Torvalds in the United States other countries or both Microsoft Windows ...

Отзывы: