33
Related service information
Error messages
Table 2. Error messages
Symptom or error
FRU or action, in sequence
Unsupported memory.
DIMM.
Make sure to use supported
memory.
Device address conflict.
1.
Load “Setup Defaults” in the BIOS
Setup Utility.
2. Backup battery.
3. System board.
Allocation error for device.
1.
Load “Setup Defaults” in the BIOS
Setup Utility.
2. Backup battery.
3. System board.
Failing bits: nnnn.
1.
DIMM
.
2. System board.
Invalid system configuration data.
1.
DIMM
.
2. System board.
I/O device IRQ conflict.
1.
Load “Setup Defaults” in the BIOS
Setup Utility.
2. Backup battery.
3. System board.
Hibernation error.
1.
Restore the system configuration
to what it was before the computer
entered hibernation mode.
2. Memory size has been changed, re-
create the hibernation file.
Fan error.
1.
Fan
.
2. Thermal grease.
3. System board.
Thermal sensing error.
System board.
Authentication of system services failed.
Press <Esc> to resume.
The Predesktop Area in the HDD is
corrupted. Restore it from a recovery disk.
Cannot boot from any device.
Check the status of device which you
want to boot from.
Device not found.
1. The device you want to boot from.
2. System board.
Device Error.
1. The device you want to boot from.
2. System board.
No valid operating system.
1. Check that the operating system has
no failure and is installed correctly.
2. Reinstall the operation system.
Excluded from boot order.
• Enter the BIOS Setup Utility and add