8 Technical data and accessories
Bauer
Temperature sensor cable
60
GEL 2444
E
nglis
h
Electrical data
Electromagnetic compatibility
Electromagnetic emissions
Electromagnetic immunity
DIN EN 61000-6-4:2011-09; DIN EN
61000-6-3:2011-09
DIN EN 61000-6-2:2006-03; DIN EN
61000-6-1:2007-10
Dielectric strength
500 V, in accordance with DIN EN
60439–1
Mechanical data
Weight
30 g
Housing material
Die cast zinc
Assured operating temperature range
-30 °C to +85 °C
Operating and storage temperature
range
-40 °C to +120 °C
Degree of protection
IP 68
Vibration resistance
200 m/s
2
, in accordance with DIN EN
60068–2–6
Shock resistance
2000 m/s
2
, in accordance with DIN EN
60068–2-27
MTTF
FIT
5,000,000 h at 55 °C
204 10
-9
h
-1
at 55 °C
Electrical connection
Number of cores x core cross-section
9 x 0.15 mm
2
Max. permitted cable length
100 m
(1)
Cable diameter
5 mm
Min. bending radius
25 mm
8.2 Temperature
sensor
cable
Cable version
Technical data
GEL 2444
␣␣␣␣␣␣␣␣␣
M
(2-core temperature sensor cable)
●
TEFLON cable 2 × 0.14 mm
2
●
Outside diameter: 2.8 mm (± 0.1)
●
Min. bending radius: 20 mm
GEL 2444
␣␣␣␣␣␣␣␣␣
N
(4-core temperature sensor cable)
●
ETFE cable 4 × 0.14 mm
2
●
Outside diameter: 3.5 mm (± 0.2)
●
Min. bending radius: 7 mm
GEL 2444
␣␣␣␣␣␣␣␣␣
P
(6-core temperature sensor cable)
●
ETFE cable 6 × 0.14 mm
2
●
Outside diameter: 3.5 mm (± 0.2)
●
Min. bending radius: 7 mm
(1)
Pay attention to voltage drop on the supply cable