Page 23
XP21 SERIES
Heat Pump Control (A175) Jumpers and Terminals
55
50
DEGREE
TARGET
45
DEGREE
TARGET
40
DEGREE
TARGET
55 50 45 40
SECOND
−
STAGE LOCK
−
IN TEMPERATURE
55 50 45 40
55 50 45 40
55 50 45 40
DEGREE
TARGET
100
90
DEGREE
TARGET
70
DEGREE
TARGET
*50
DEGREE
TARGET
100 90 70 50
DEGREE
TARGET
DEFROST TERMINATION TEMPERATURE
100 90 70 50
100 90 70 50
100 90 70 50
30
0
COMPRESSOR SHIFT DELAY
*30
SECOND DELAY
SECOND DELAY
0
LED ALERT CODES
LED ALERT CODES
INDICATES RS−BUS DATA
COMMUNICATION IS ACTIVE.
(COMMUNICATION MODE
ONLY)
Table 3 on page 24 provides additional information concerning jumpers, links, and connections for the heat pump control.
E37
E47
DS12
E48
E34
DS11 and DS14
DS13 and DS15
JUMPER REMOVED − NO SECOND STAGE LOCK−IN TEMPERATURE.
E33
TEST PINS (SEE
FIGURE 28 FOR
DESCRIPTION OF
VARIOUS FUNCTIONS)
HEAT PUMP CONTROL TWO STAGE
CUT FOR HUMIDITROL APPLICATION
(TWO−STAGE UNITS ONLY)
W1
*NO JUMPER
NOTE Earlier produce units will have a default factory setting (jumper
present) for 40ºF. Later produce units will have no jumper by default present
on E48.
Figure 16. Heat Pump Control Connections, Jumper Settings and LED Locations