XC17 - 2 to 5 Ton Air Conditioner / Page 48
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER
EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC17-060-230
TXV
57,000
15.00
12.20
CH33-62D
4096604
XC17-060-230
TXV
56,500
15.20
12.20
CR33-50/60
G61MPV-60C-090
4096611
XC17-060-230
TXV
56,000
15.20
12.20
CR33-50/60
G61MPV-60C-091
4096613
XC17-060-230
TXV
57,000
15.20
12.50
CR33-50/60
G61MPV-60C-110
4096614
XC17-060-230
TXV
56,500
15.20
12.20
CR33-50/60
G61MPV-60C-111
4096616
XC17-060-230
TXV
57,000
15.50
12.50
CR33-50/60
SL280DF090V60C
4096608
XC17-060-230
TXV
57,000
15.50
12.70
CR33-50/60
SL280DF110V60C
4096610
XC17-060-230
TXV
56,000
15.20
12.50
CR33-50/60
SLP98DF090V60C
4096612
XC17-060-230
TXV
56,000
15.20
12.20
CR33-50/60
SLP98DF110V60C
4096615
XC17-060-230
TXV
56,000
15.00
12.20
CR33-50/60
4096601
XC17-060-230
TXV
57,000
15.50
12.50
CR33-60
G61MPV-60D-135
4096618
XC17-060-230
TXV
56,000
15.00
12.20
CR33-60
4096602
XC17-060-230
TXV
57,000
15.20
12.50
CX34-49
G61MPV-60C-090
4096570
XC17-060-230
TXV
56,500
15.20
12.50
CX34-49
G61MPV-60C-091
4096572
XC17-060-230
TXV
57,500
15.20
12.50
CX34-49
G61MPV-60C-110
4096573
XC17-060-230
TXV
57,500
15.20
12.50
CX34-49
G61MPV-60C-111
4096575
XC17-060-230
TXV
57,500
15.50
12.70
CX34-49
SL280UH090V60C
4096567
XC17-060-230
TXV
57,500
15.50
12.70
CX34-49
SL280UH090XV60C
4235813
XC17-060-230
TXV
57,000
15.50
12.70
CX34-49
SL280UH110V60C
4096569
XC17-060-230
TXV
56,500
15.20
12.50
CX34-49
SLP98UH090V60C
4096571
XC17-060-230
TXV
57,500
15.20
12.50
CX34-49
SLP98UH110V60C
4096574
XC17-060-230
TXV
57,500
15.20
12.50
CX34-49
4096562
XC17-060-230
TXV
57,500
15.70
12.70
CX34-60D
G61MPV-60D-135
4096578
XC17-060-230
TXV
57,500
15.50
12.70
CX34-60D
SL280UH135V60D
4096577
XC17-060-230
TXV
57,000
15.70
12.70
CX34-60D
SLP98UH135V60D
4096579
XC17-060-230
TXV
57,000
15.00
12.20
CX34-60D
4096563
XC17-060-230
TXV
58,500
15.70
12.70
CX34-62C
G61MPV-60C-090
4096584
XC17-060-230
TXV
58,000
15.70
12.70
CX34-62C
G61MPV-60C-091
4096586
XC17-060-230
TXV
59,000
15.70
12.70
CX34-62C
G61MPV-60C-110
4096587
XC17-060-230
TXV
59,000
15.70
12.70
CX34-62C
G61MPV-60C-111
4096589
XC17-060-230
TXV
59,000
16.00
13.00
CX34-62C
SL280UH090V60C
4096581
XC17-060-230
TXV
59,000
16.00
13.00
CX34-62C
SL280UH090XV60C
4235814
XC17-060-230
TXV
58,500
16.00
13.00
CX34-62C
SL280UH110V60C
4096583
XC17-060-230
TXV
58,000
15.70
12.70
CX34-62C
SLP98UH090V60C
4096585
XC17-060-230
TXV
59,000
15.70
12.70
CX34-62C
SLP98UH110V60C
4096588
XC17-060-230
TXV
59,000
15.50
12.70
CX34-62C
4096564
XC17-060-230
TXV
58,000
15.70
13.00
CX34-62D
G61MPV-60D-135
4096592
XC17-060-230
TXV
57,500
16.00
13.20
CX34-62D
SL280UH135V60D
4096591
XC17-060-230
TXV
58,000
15.70
13.00
CX34-62D
SLP98UH135V60D
4096593
XC17-060-230
TXV
58,000
15.20
12.50
CX34-62D
4096565
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (
58M81
) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.