AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER
EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC17-036-230
TXV
35,600
16.50
14.00
C33-50/60C
G61MPV-60C-110
3844495
XC17-036-230
TXV
35,600
16.50
14.00
C33-50/60C
G61MPV-60C-111
3844497
XC17-036-230
TXV
35,600
16.70
14.00
C33-50/60C
SL280UH090V60C
4036835
XC17-036-230
TXV
35,600
16.70
14.00
C33-50/60C
SL280UH090XV60C
4235575
XC17-036-230
TXV
35,400
16.50
14.00
C33-50/60C
SL280UH110V60C
4036841
XC17-036-230
TXV
35,400
16.50
14.00
C33-50/60C
SL280UH110XV60C
4040547
XC17-036-230
TXV
35,200
16.50
14.00
C33-50/60C
SLP98UH090V36C
4035369
XC17-036-230
TXV
35,600
16.50
13.70
C33-50/60C
SLP98UH090V60C
4035370
XC17-036-230
TXV
35,600
16.50
14.00
C33-50/60C
SLP98UH110V60C
4035371
XC17-036-230
TXV
36,200
17.00
14.20
C33-62C
G61MPV-36C-090
3844500
XC17-036-230
TXV
36,600
16.70
14.20
C33-62C
G61MPV-60C-090
3844502
XC17-036-230
TXV
36,600
16.50
14.00
C33-62C
G61MPV-60C-091
3844503
XC17-036-230
TXV
36,600
17.00
14.20
C33-62C
G61MPV-60C-110
3844504
XC17-036-230
TXV
36,600
17.00
14.20
C33-62C
G61MPV-60C-111
3844506
XC17-036-230
TXV
36,600
17.20
14.50
C33-62C
SL280UH090V60C
4036844
XC17-036-230
TXV
36,600
17.20
14.50
C33-62C
SL280UH090XV60C
4235572
XC17-036-230
TXV
36,600
17.00
14.20
C33-62C
SL280UH110V60C
4036848
XC17-036-230
TXV
36,600
17.00
14.20
C33-62C
SL280UH110XV60C
4040544
XC17-036-230
TXV
36,400
17.00
14.20
C33-62C
SLP98UH090V36C
4035372
XC17-036-230
TXV
36,200
17.00
14.50
C33-62C
SLP98UH090V48C
4035373
XC17-036-230
TXV
36,800
17.00
14.20
C33-62C
SLP98UH090V60C
4035374
XC17-036-230
TXV
36,600
17.20
14.50
C33-62C
SLP98UH110V60C
4035375
XC17-036-230
TXV
35,800
15.20
13.00
C33-62C
3844357
XC17-036-230
TXV
34,600
16.20
13.70
CBX27UH-036
3844584
XC17-036-230
TXV
35,600
17.00
14.20
CBX27UH-042
3844585
XC17-036-230
TXV
33,800
15.00
12.70
CBX32M-030
3844580
XC17-036-230
TXV
34,000
15.00
12.70
CBX32M-036
3844581
XC17-036-230
TXV
34,000
15.00
12.70
CBX32M-042
3844582
XC17-036-230
TXV
35,200
15.70
13.20
CBX32M-048
3844583
XC17-036-230
TXV
34,200
15.70
13.20
CBX32MV-024/030
3844586
XC17-036-230
TXV
34,600
16.00
13.50
CBX32MV-036
3844587
XC17-036-230
TXV
35,800
17.00
14.50
CBX32MV-048
3844588
XC17-036-230
TXV
34,000
16.50
13.50
CBX40UHV-036
3844589
XC17-036-230
TXV
35,000
17.20
14.00
CBX40UHV-042
3844590
XC17-036-230
TXV
35,200
17.50
14.20
CBX40UHV-048
3844591
XC17-036-230
TXV
34,000
15.50
13.20
CH23-41
G61MPV-36B-045
3844533
XC17-036-230
TXV
34,000
15.70
13.20
CH23-41
G61MPV-36B-070
3844534
XC17-036-230
TXV
34,000
15.70
13.20
CH23-41
G61MPV-36B-071
3844536
XC17-036-230
TXV
34,200
16.20
13.70
CH23-41
G61MPV-36C-090
3844537
XC17-036-230
TXV
34,400
16.00
13.50
CH23-41
SL280UH070V36A
3946897
XC17-036-230
TXV
34,400
16.00
13.50
CH23-41
SL280UH070XV36A
4037960
XC17-036-230
TXV
34,200
16.50
13.70
CH23-41
SL280UH090V36B
3946898
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (
58M81
) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.