DC Inverter Multi VRF System
1
1 Safety Notices (Please Be Sure to Abide)
WARNING:
If not abide strictly, it may cause severe damage to the unit or the people.
NOTE:
If not abide strictly, it may cause slight or medium damage to the unit or the people.
This sign indicates that the operation must be prohibited. Improper operation may cause
severe damage or death to people.
This sign indicates that the items must be observed. Improper operation may cause damage
to people or property.
WARNING!
This product can’t be installed at corrosive, inflammable or explosive environment or the
place with special requirements, such as kitchen. Otherwise, it will affect the normal operation
or shorten the service life of the unit, or even cause fire hazard or serious injury. As for above
special places, please adopt special air conditioner with anti-corrosive or anti-explosion
function.
This Multi VRF System shall only be connected to an appliance suitable for the same
refrigerant.
All outdoor units in Manual Cover is a partial unit, complying with partial unit of IEC
60335-2-40:2018, and must only be connected to other units that have been confirmed as
complying to corresponding partial unit requirements of this international standard.
The electrical interface shall comply with electrical security requirement, voltage shall be
220-240(50Hz) or 208-230(60Hz), current shall be referred to the table of “Selection of circuit
breaker and power cord” in Section 4.6.2, and safety class of construction is I.
Please install the unit
according to instructions in
this manual. Read this manual
carefully before starting up or
checking the machine.
Installation should be
performed by distributor or
qualified technicians. Do not
install the product by yourself.
Improper installation may
result in water leakage,
electric shock or fire hazard.
Before installation, please
check the power cord if it
complies with the power
supply requirement on the
nameplate. Make sure the
power supply is safe.
This air conditioner must be
properly grounded through the
receptacle to avoid electric
shock. The ground wire
shouldn’t be connected with
gas pipe, water pipe, lightning
arrester or telephone line.
When installing, specialized
parts and accessories must
be used. Otherwise, it may
result in water leakage,
electric shock or fire hazard.
R410A refrigerant can
produce poisonous gas once it
meets fire, so please ventilate
the room immediately if
refrigerant leaks out during
installation.