background image

Multi Variable Air Conditioners Fresh Air Series Indoor Unit 

 

1 Safety Precautions   

 

WARNING!

 If not abide strictly, it may cause severe damage to the unit or the people. 

 

NOTE! 

If not abide strictly, it may cause slight or medium damage to the unit or the 

people. 

 

This sign indicates that the operation must be prohibited. Improper operation may 

cause severe damage or death to people. 

 

This sign indicates that the items must be observed. Improper operation may cause 

damage to people or property. 

 

WARNING!   

This product can’t be installed at corrosive, inflammable or explosive environment or the 

place with special requirements, such as kitchen. Otherwise, it will affect the normal operation 
or shorten the service life of the unit, or even cause fire hazard or serious injury. As for above 
special places, please adopt special air conditioner with anti-corrosive or anti-explosion 
function .   

This Multi  VRF System shall only be connected to an appliance suitable for the same 

refrigerant. 

All  units in Manual Cover is a partial unit, complying with partial unit of IEC 

60335-2-40:2018, and must only be connected to other units that have been confirmed as 
complying to corresponding partial unit requirements of this international standard. 

The electrical interface shall comply with electrical security requirement, voltage shall be 

220-240V~50Hz or 208-230V~60Hz,current shall be referred to the table of “Dimension of 
power cord and capacity of air switch” in Section 3.4, and safety class of construction is I. 

 

Follow this instruction to 

complete the installation work. 

Please carefully read this 

manual before unit startup and 

service.

 

 

Installation should be 

conducted by dealer or 

qualified personnel. 

Please do not attempt to 

install the unit by 

yourself. Improper 

handling may result in 

water leakage, electric 

shock or fire disaster etc.

 

 

Before installation, please 
check if the power supply is in 

accordance with the 

requirements specified on the 

nameplate. And also take care 

of the power safety. 

 

Make sure the unit can be 

earthed properly and 

soundly after plugging 

into the socket so as to 

avoid electric shock. 

Please do not connect 

the ground wire to gas 

pipe, water pipe, lightning 

rod or telephone line. 

 

Be sure to use the exclusive 

accessory and part to prevent 

the water leakage, electric 

shock and fire accidents. 

 

If refrigerant leakage 

happens during 

installation, please 

ventilate immediately. 

Poisonous gas will 

emerge if the refrigerant 

gas meets fire. 

Содержание VEOA042N432U

Страница 1: ...resh Air Evaporator Types Thank you for selecting LENNOX air conditioners Please read this manual carefully before operation and keep it for further reference K 230 60 3 and 220 50 3 N 380V 50 60Hz 3P...

Страница 2: ...perly select the model according to actual using environment otherwise it may impact the using convenience 4 This product has gone through strict inspection and operational test before leaving the fac...

Страница 3: ...Notice This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given s...

Страница 4: ...nstallation and Test of Drain Pipe 11 4 4 Installation of Air Duct 14 4 5 Installation of Wired Controller 16 5 Wiring Work 16 5 1 Connection of Wire and Patch Board Terminal 17 5 2 Power Cord Connect...

Страница 5: ...been confirmed as complying to corresponding partial unit requirements of this international standard The electrical interface shall comply with electrical security requirement voltage shall be 220 2...

Страница 6: ...il supplied heating equipment is used Never start up or shut off the air conditioner by means of directly plug or unplug the power cord Turn off the unit after it runs at least five minutes otherwise...

Страница 7: ...r series indoor unit 1 If the selected air volume 2500m3 h connect with normal indoor units by blow method or connect with the fixed outdoor unit as shown in 2 Model of Indoor Unit Model of Outdoor Un...

Страница 8: ...N432U VEOA096N432U or VEOA076N432U or VEOA096N432U VEOA096N432U VEOA096N432U or VEOA076N432U or VEOA096N432U Note F is for the power specification of 208 230V 3 60Hz U is for the power specification o...

Страница 9: ...t To be used for connecting the refrigerant pipe 3 Corrugated pipe 1 VEOA042 48N432U 4 M10 Nut Nut with Washer M10 8 4 PC To be used together with the hanger bolt for installing the unit 5 M10 Nut M10...

Страница 10: ...ke sure the space for maintenance please install the indoor unit according to the dimension described below 6 Keep the unit away from heat source inflammable gas or smoke 7 This is a concealed ceiling...

Страница 11: ...IEC 53 L 250 820 1 5 2 0 75 2 1 25 2 AWG18 2 AWG16 IEC 60227 5 1 The cord shall be Circular cord the cores shall be twisted together 2 If unit is installed in places with intense magnetic field or st...

Страница 12: ...wer cord size Power cord size is based on multicore copper core cable with operation temperature of 90 C when laying on wire groove at 40 C ambient temperature IEC 60364 5 523 If the operation conditi...

Страница 13: ...92 327 1483 791 385 VEOA084N432U 1353 632 992 1150 192 327 1483 791 385 VEOA096N432U 1353 632 992 1150 192 327 1483 791 385 4 1 2 Punching of Bolt Spots and Bolt Installation 1 Cut out the installatio...

Страница 14: ...specialized nut to secure the unit Fig 4 1 6 NOTES Before installation please finish the preparation work of all pipes connection pipe drain pipe and wires wired controller wire connection wire of ID...

Страница 15: ...mm Torque N m 6 35 15 30 9 52 35 40 12 7 45 50 15 9 60 65 Fig 4 2 3 The pipe should not be bent too much or it may crack Use a pipe bender when bending the pipe 4 Use a sponge to wrap the uninsulated...

Страница 16: ...use adhesives to connect drain hole and drain hose 8 When the drain pipe is used for several equipments the shared pipe should be about 100mm lower than the drain hole of each equipment In this case...

Страница 17: ...elbow Fig 4 3 7 No 3 Inserting pipe connection Fig 4 3 8 Fig 4 3 6 Fig 4 3 7 Fig 4 3 8 9 Drain pipes should have a downward slope of at least 1 2 in order to prevent pipes from sagging install hanger...

Страница 18: ...tion of air duct should be well sealed in order to prevent air leakage The design and construction of air duct should comply with national requirements The edge of air return duct is suggested to be m...

Страница 19: ...t Fig 4 4 2 No Name No Name 1 Fresh Air Duct 6 Transition Pipe 2 Canvas Duct 7 Supply Air Duct 3 Fresh Air Blinds 8 Diffuser 4 Hanger Rod 9 Diffuser Connector 5 Supply Air Outlet 4 4 2 Shape and Size...

Страница 20: ...o ensure safe and correct operation Install specialized branch circuit breaker according to related laws and regulations and electrical standards All wiring must use pressure terminal or single wire M...

Страница 21: ...f stranded wire as shown in fig 5 1 2 1 Strip about 10mm insulation of the end of stranded wire by stripping and cutting tool 2 Loosen the wiring screws on terminal board 3 Insert the wire into the ri...

Страница 22: ...with clamp of electric box 5 For more reliable communication make sure connect the terminal resistor to the most downstream IDU of the communication bus terminal D1 and D2 as shown in fig 5 3 2 termin...

Страница 23: ...same time When operating through a remote controller both wired controller and the receiving light board can receive the signals as shown in Fig 5 4 3 Fig 5 4 3 5 5 Illuminate for Connection of Wired...

Страница 24: ...the same address For specific setting methods please refer to installation manual of wired controller If connecting the fresh air indoor unit with wired controller for operation fresh air indoor unit...

Страница 25: ...characters on the wired controller screen will disappear after cutting off the power supply 7 Table of Error Codes for Indoor Unit Error Code Content Error Code Content Error Code Content L0 Indoor U...

Страница 26: ...or blocked Too heavy heat load of room e g too many people Door or windows is open Air inlet and outlet of IDU are blocked Set temperature is too high or refrigerant leaks The performance of room temp...

Страница 27: ......

Страница 28: ...5 718 2901 C 01 ennox Industries Inc For a complete list of the registered and common law trademarks owned by Lennox Industries Inc please visit www lennox com LennoxGlobalHVAC Lennoxintl com 2019 Len...

Отзывы: