WARNING

Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a qualified installer or service agency.

CAUTION

Physical contact with metal edges and corners while
applying excessive force or rapid motion can result in
personal injury. Be aware of, and use caution when
working near these areas during installation or while
servicing this equipment.

IMPORTANT

The Clean Air Act of 1990 bans the intentional venting of
refrigerant (CFCs and HCFCs and HFCs) as of July 1,
1992. Approved methods of recovery, recycling or
reclaiming must be followed. Fines and/or incarceration
may be levied for noncompliance.

IMPORTANT

This unit must be matched with an outdoor unit as spe-
cified in Lennox Engineering Handbook.

INSTALLATION
INSTRUCTIONS

CB(X)26UH(−R)

 

Series Units

AIR HANDLERS

505,059M (65937170)
07/11
Supersedes 05/11

Table of Contents

Shipping and Packing List

1

. . . . . . . . . . . . . . . . . . . . . . 

Unit Dimensions 

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

CB(X)26UH Series Units

3

. . . . . . . . . . . . . . . . . . . . . . . 

Requirements

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Installation Clearances

4

. . . . . . . . . . . . . . . . . . . . . . . . . 

Installation

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Condensate Drain

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Duct System and Filters

8

. . . . . . . . . . . . . . . . . . . . . . . . 

Connecting Refrigerant Lines

9

. . . . . . . . . . . . . . . . . . . 

Sealing the Unit

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Electrical Connections

9

. . . . . . . . . . . . . . . . . . . . . . . . . 

Airflow − Cooling Blower Speed

12

. . . . . . . . . . . . . . . . . . 

Check−Out Procedures

15

. . . . . . . . . . . . . . . . . . . . . . . . . 

Operation

15

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Maintenance

16

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Accessories

16

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Cabinet Insulation

16

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Shipping and Packing List

Package 1 of 1 contains the following:

1 − Assembled air handler unit for upflow or horizontal air

discharge application (includes upflow and horizontal
drain pans)

NOTE  For downflow application, order kit 12W61
(0658731−75).

Check equipment for shipping damage. If found,
immediately report damage to the last carrier. Check the
unit rating plate to confirm that delivered unit matches
order.

WARNING

Product contains fiberglass wool.

Disturbing the insulation in this product during installa-
tion, maintenance, or repair will expose you to fiberglass
wool. Breathing this may cause lung cancer. (Fiberglass
wool is known to the State of California to cause cancer.)

Fiberglass wool may also cause respiratory, skin, and
eye irritation.

To reduce exposure to this substance or for further infor-
mation, consult material safety data sheets available
from address shown below, or contact your supervisor.

Lennox Industries Inc.
P.O. Box 799900
Dallas, TX 75379−9900

Litho U.S.A.

Содержание CB26UH series

Страница 1: ... Unit Dimensions 2 CB X 26UH Series Units 3 Requirements 3 Installation Clearances 4 Installation 4 Condensate Drain 7 Duct System and Filters 8 Connecting Refrigerant Lines 9 Sealing the Unit 9 Electrical Connections 9 Airflow Cooling Blower Speed 12 Check Out Procedures 15 Operation 15 Maintenance 16 Accessories 16 Cabinet Insulation 16 Shipping and Packing List Package 1 of 1 contains the follo...

Страница 2: ... for Upflow and LH RH Horizontal Air Discharge Applications Dimension 018 024 030 036 037 042 048 060 inches mm inches mm inches mm inches mm A 46 3 4 1187 51 1295 54 1372 60 1524 B 18 1 2 470 21 1 4 540 21 1 4 540 21 1 4 540 C 22 559 22 559 26 660 26 660 D 11 279 12 1 2 318 12 305 11 3 4 298 E 16 406 18 1 2 470 16 3 4 425 17 432 F 5 1 2 140 6 152 4 102 4 102 G 13 1 2 343 16 406 16 406 16 406 H 19...

Страница 3: ...pe Warm Air Heating and Air Conditioning Systems NFPA No 90B IMPORTANT The CB X 26UH units are designed to match and must be used with outdoor units as rated The indoor sections are manufactured with a check expansion valve TXV or refrigerant flow control RFC device to provide opti mum refrigerant control and system performance with a variety of different capacities of outdoor units TXV units In s...

Страница 4: ... free flow of return air Installation GENERAL INFORMATION WARNING Improper installation adjustment alteration service or maintenance can cause property damage personal inju ry or loss of life Installation and service must be per formed by a qualified installer or service agency CB X 26UH units are factory assembled and configured for installation in upflow or horizontal left hand air discharge app...

Страница 5: ... cabinet integrity Ensure that there is adequate room to remove service and access panels if installing in the horizontal position 1 Determine whether left hand or right hand air discharge is required If right hand is required perform Right Hand Discharge Modification on page 6 2 Determine knockouts required for drain line connections 3 With access door removed knock out drain line opening for ins...

Страница 6: ...OW OFF PREVENTION BRACKET S AND DRIP SHIELD FROM HERE THEN REINSTALL PAN HERE REINSTALL BRACKET HERE NOTE EXPANSION VALVE SHOWN ON COIL IS NOT ON CB26UH R RFC EQUIPPED UNITS Figure 7 Field Modification for Right Hand Discharge OPEN END FOR CONDENSATION DRAIN COIL ASSEMBLY PLUGGED END Figure 8 Right Hand Drain Plug Location REFRIGERANT METERING DEVICE NOTE See the outdoor unit installation instruct...

Страница 7: ... making drain fitting connections to the drain pan hand tighten the fitting and use a sealant Over tightening the fittings can split connections on the drain pan 3 If the auxiliary drain line is to be used remove the plug and route the drain line so that water draining from the outlet will be easily noticed by the homeowner 4 After removal of drain pan plugs check the drain port to see if holes ha...

Страница 8: ... DRAIN Test the drain pan and drain line after installation 1 Pour several quarts of water into drain pan enough to fill drain trap and line 2 Check to make sure the drain pan is draining completely no leaks are found in drain line fittings and water is draining from the end of the primary drain line 3 Correct any leaks found Duct System and Filters DUCT SYSTEM The air handler is provided with fla...

Страница 9: ...s This is especially important when the unit is installed in an unconditioned area WARNING There must be an airtight seal between the bottom of the air handler and the return air plenum Use fiberglass sealing strips caulking or equivalent sealing method between the plenum and the air handler cabinet to ensure a tight seal Return air must not be drawn from a room where this air handler or any gas f...

Страница 10: ... ground terminal marked GND Failure to do so can result in death or elec trical shock 4 Use UL listed wire nuts to connect the field supply conductors to the unit black and yellow leads and the ground wire to ground terminal marked GND 5 Replace the air handler access panel GND CONNECT BLACK TO BLACK CONNECT UNIT S YELLOW CONDUC TOR TO WHITE FIELD SUPPLY CONDUCTOR CONNECT GROUND WIRE TO GROUND TER...

Страница 11: ...Page 11 CB X 26UH SERIES WARNING USE COPPER CONDUCTORS ONLY Figure 13 Wiring Diagram ...

Страница 12: ...NGE BLOWER SPEED NOTE Refer to wiring diagram figure 13 and blower performance table 4 WARNING Electric shock hazard Disconnect all power supplies before servicing Replace all parts and panels before op erating Failure to do so can result in death or elec trical shock 1 Disconnect all power supplies 2 Remove the air handler access panel 3 Locate pin number 2 on the blower relay Two black wires are...

Страница 13: ...75 365 036 LOW SPEED 10 25 1560 705 1405 635 20 50 1480 670 1340 610 30 75 1390 630 1270 575 40 100 1290 585 1185 540 50 125 1170 530 1090 495 60 150 1015 480 975 460 037 LOW SPEED 10 25 1570 740 1330 625 20 50 1520 715 1310 620 30 75 1440 680 1250 590 40 100 1300 615 1180 555 50 125 1170 550 1070 505 60 150 950 450 840 395 042 MEDIUM SPEED 10 25 1940 880 1785 810 20 50 1845 835 1705 775 30 75 174...

Страница 14: ...8 0 40 100 813 384 963 454 1121 529 0 50 125 721 340 886 418 1033 487 0 60 150 036 LOW SPEED 0 10 25 1135 536 1354 639 1494 705 0 20 50 1120 529 1345 635 1469 693 0 30 75 1112 525 1317 621 1417 669 0 40 100 1079 509 1260 595 1336 630 0 50 125 995 470 1090 514 1250 590 0 60 150 042 MEDIUM SPEED 0 10 25 1202 567 1404 663 1540 727 0 20 50 1192 563 1413 667 1530 722 0 30 75 1160 547 1386 654 1507 711 ...

Страница 15: ...mperature The indoor blower and auxiliary heat should come on together Allow a minimum of 3 minutes for all sequencers to cycle on S Set the thermostat so that it does not call for heat Allow up to 5 minutes for all sequencers to cycle off Operation COOLING COOLING ONLY OR HEAT PUMP When the thermostat calls for cooling 24 volts is put on the blower time delay relay coil After a delay the indoor b...

Страница 16: ...y drain line a problem exists which should be investigated and corrected Contact a qualified service technician Cabinet Insulation IMPORTANT DAMAGED INSULATION MUST BE REPAIRED OR REPLACED before the unit is put back into operation In sulation loses its insulating value when wet damaged separated or torn Matt or foil faced insulation is installed in indoor equipment to provide a barrier between ou...

Отзывы: