4
Figure 13. Remove Heat Kit Access Panel
11. Remove the heat kit access panel. Retain
screws for use in securing the heating
element in a later step. See Figure 13.
NOTE -
For V8EH0050P-1P, V8EH0080P-1P and
V8EH0100P-1P, remove only one panel.
Figure 14. Position Heating Elements
12. Align the electric heat kit with the air handler unit
and slide the heating element into the heat kit
opening. The prongs on the back of the heating
elements must be inserted into the holes in the
back of the VVCA unit. See Figure 14.
17. Secure the circuit breaker panel onto the lip at the
front of the control box with the two short screws.
See Figure 17.
Figure 15. Install Grounding Terminal
13. Secure the mounting plate with the screws
removed in Step 11.
14. Reinstall the main control board and terminal strip
assembly with the screws removed in step 3.
15. Install the grounding terminal as shown in Figure
15.
16. Secure the relay to the bottom of the VVCA control
box as shown in Figure 16.
Figure 17. Secure Circuit Breaker Panel
Figure 16. Secure Relay