background image

TROUBLESHOOTING 

 

PAGE 24 

OVERFIRING DAMAGE 

If the heater or chimney connector glows, you are overfir-
ing. Other symptoms may include: Cracking, warping or 
burning out of components, stove glass may develop a 
haze, which will not come off with cleaning. 
 
Overfiring of a stove is a condition where excessive tem-
peratures are reached, beyond the design capabilities of 
the appliance. The damage that occurs from overfiring is 
not covered under the manufacturers limited warranty. 
 
The following are a few conditions that should be evalu-
ated and (corrected if necessary) if an overfiring condi-
tion is suspected: 
 

Overfiring Caused From Improper Installation 

Ensure that all installation requirements have been met 
as outlined in the installation manual. The chimney 
should be clean and in good repair. A draft test should be 
performed to determine if the draft requirements of the 
appliance are being met. A draft gauge should read be-
tween .05 and .06 " W.C. (inches water column). Exces-
sive draft (above .06 " W.C.) will allow too much combus-
tion air to be pulled in which results in hotter burns. Too 
little draft (below .05 " W.C.) will not allow enough com-
bustion air delivery to maintain a fire (this may result in 
improper operation of appliance, i.e. wont maintain fire 
unless fuel loading door is left open. See following,

 Over-

firing Caused From Improper Operation). 

 

Overfiring Caused From Improper Operation 

Operate this appliance only as outlined in this manual. 
Never burn the appliance with either fuel loading door 
open or ajar. Do not operate this stove with the Primary 
Air Draft Control in the full "open" position for extended 
periods. This wastes fuel and can cause dangerous 
overfiring conditions. NEVER leave the stove unattended 
on high settings. 
 

Overfiring Caused From Improper Maintenance 

Strictly adhere to all maintenance requirements at fre-
quent intervals as prescribed in this manual including 
cleaning of flue and stove. Should either fuel loading 
door or glass gaskets become worn or damaged, they 
should be replaced. 
 

Overfiring Caused From Improper Fuel 

This appliance is approved for use with natural dry well-
seasoned wood only (ask your authorized dealer what 
are approved fuels for your area). Do not burn garbage, 
particleboard scraps, or pressed logs because they can 
produce conditions that will deteriorate metal. Do not 
overload or use kindling wood or mill ends as primary 
fuel as this may cause overfiring. 

Содержание Spectra CI1000HT

Страница 1: ...THESE INSTRUCTIONS FOR FUTURE REFERENCE EPA CERTIFIED WOOD BURNING STOVE THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER READ ENTIRE MANUAL THOROUGHLY BEFORE INSTALLATION P N 775 080M Rev F...

Страница 2: ...fluid or similar liquids to start or freshen up a fire in this heater Keep all such liquids well away from the heater while it is in use 11 DO NOT OVERFIRE If heater or chimney connec tor glows you ar...

Страница 3: ...cern for aesthetics efficiency and our environment We extend our continued support to help you achieve the maximum benefit and enjoy ment available from your new wood stove It is our goal at Lennox He...

Страница 4: ...to disperse its heat and therefore a central location is often best There are other practical consid erations which must be considered before a final selec tion of locations is made Existing Chimneys...

Страница 5: ...g minimum thickness required TM minimum thickness required for alternate material kM k value per inch of alternate material TL minimum thickness of listed material rM r value per inch of alternate mat...

Страница 6: ...s required TM minimum thickness required for alternate material kM k value per inch of alternate material TL minimum thickness of listed material rM r value per inch of alternate material Using the k...

Страница 7: ...ickness required TM minimum thickness required for alternate material kM k value per inch of alternate material TL minimum thickness of listed material rM r value per inch of alternate material Using...

Страница 8: ...tor pipe with factory built chimney listed to either UL 103HT or ULC S629 The use of a pipe shield for 6 connector with 1 clearance to the pipe is mandatory Minimum Clearances Inches A 21 1 2 546mm D...

Страница 9: ...tallations clearances C and F are not applicable Use listed double wall chimney connector or Type L vent pipe to the top of the stove Minimum Clearances Inches A 14 1 2 368mm D 10 254mm B 28 1 2 724mm...

Страница 10: ...y built ceiling support package use the manufacturer s transition piece usually called a dripless connector to join single wall pipe to their factory built chimney section When Using Approved Double W...

Страница 11: ...h can effect the draft The installation must be only in units with a newly constructed chimney free of creosote deposits The barometric damper is an automatic device designed to regulate the draft in...

Страница 12: ...draft gauge manu facturers instructions to create a draft test port Note Hole location should be a minimum of 1 foot above flue outlet collar 4 Start a fire See How To Start And Maintain A Fire on pa...

Страница 13: ...of direction change This appliance re quires 12 to 15 feet of effective draft for optimum perform ance see Draft Requirements on page 12 First section of pipe must be vertical Use as much straight ver...

Страница 14: ...m the outer surface of the wall thimble to wall combustibles Support the wall thimble and cover its opening with a 24 gage minimum sheet metal support Maintain the 6 153 mm space There should also be...

Страница 15: ...temperatures and to the left for lower temperatures Generally you will want to set the draft control some where in the low or medium range Tips Adjust the primary air control to a medium to low setti...

Страница 16: ...a bed of coals has been established adjust the primary air control to a lower setting AND CLOSE THE START UP AIR CONTROL AIR DELIVERY SYSTEMS Tip Using the air control tool adjust the primary air draf...

Страница 17: ...expect and how long the fire will burn It may take a week or two to learn but your patience will be rewarded by the warmth and pleasant satisfaction that only a wood fire can pro vide REPLENISH HUMIDI...

Страница 18: ...prevent smoke blowing into the room follow these recommendations 1 Using the air control tool adjust the primary air draft control and start up air control to the full open posi tion and let the fire...

Страница 19: ...ted adjust the primary air to a medium high position for approximately 20 25 minutes after the start up air is closed before adjusting to a lower setting This helps to establish the draft and it reduc...

Страница 20: ...h to ensure good air circulation on both sides leaving adequate space between woodpiles to walk com fortable Do not stack wood against a wall or building It helps to elevate the woodpiles off the grou...

Страница 21: ...hould not be used to carry the ash pan Use a leather glove and hold the ash pan on both sides CAUTION MAKE SURE THAT THE FIRE IS OUT AND THE STOVE IS COLD BEFORE REMOVING ASHES Ashes can hold live emb...

Страница 22: ...air draft control to a medium high or high setting for a 10 minute period each day Do not attempt to burn out heavy creosote accumulations in this manner This must be removed from the chimney by scrap...

Страница 23: ...open or provide an outside source of air near stove 7 Insufficient vertical height to chimney to achieve ade quate draft Does Not Produce Enough Heat 1 Using green or insufficiently cured wood 2 Exce...

Страница 24: ...C will not allow enough com bustion air delivery to maintain a fire this may result in improper operation of appliance i e wont maintain fire unless fuel loading door is left open See following Over...

Страница 25: ...grams hr 4 42 grams Maximum Log length 18 457 mm Firebox Size 1 12 cu feet Loading Front Side Width overall 23 3 4 604 mm Depth overall 15 5 16 389 mm Height to flue 30 762 mm Height to stove top 27...

Страница 26: ...ams hr 2 72 grams Maximum Log length 22 559 mm Firebox Size 1 97 cu feet Loading Front Side Width overall 29 1 8 740 mm Depth overall 18 3 4 476 mm Height to flue 32 13 16 833 mm Height to stove top 2...

Страница 27: ...Includes Gasket Hardware CI2000HT 40M0701 3 Door Ashpan Charcoal Handle Receiver Not Included CI1000HT 40M4301 4 Door Ashpan Charcoal Handle Receiver Not Included CI2000HT 40M1701 1 Door Firebox Char...

Страница 28: ...e Pin Set Side Door Includes Hinge Pins 2 Acorn Nuts 2 Washers CI1000HT CI2000HT 41M0901 28 Leg Front Left Charcoal Includes Gasket Hardware CI1000HT CI2000HT 40M9501 28 Leg Front Right Charcoal Inclu...

Страница 29: ...ries 5 Bottom Center Firebrick CI2000HT Series 6 Bottom Side Firebrick CI2000HT Series 7 Left Lower Firebrick CI2000HT Series 8 Upper Left Firebrick CI2000HT Series 9 Lower Rear Firebrick CI2000HT Ser...

Страница 30: ...rebrick above tubes on ceiling CI1000HT Series 16 Upper Rear Firebrick CI1000HT Series 17 Fuel Grate Frame CI1000HT Series 18 Fuel Grate Frame CI2000HT Series 19 Air Column Gasket CI1000HT CI2000HT Se...

Страница 31: ...eries 24 Ashpan Door Hinge Pin CI1000HT CI2000HT Series 25 Front Firebox Door Hinge Pin CI1000HT Series 26 Front Firebox Door Hinge Pin CI2000HT Series 27 Side Door Hinge Pin CI1000HT CI2000HT Series...

Страница 32: ...es 35 Ashlip CI1000HT CI2000HT Series 36 Ashpan CI1000HT CI2000HT Series 37 Baffle Assembly Ceramic Fiber Brick above secondary air tubes CI2000HT Series 38 Start up Air Channel Assembly CI2000HT Seri...

Страница 33: ...Shown CI1000HT Firebrick Placement Diagram 15 Baffle Firebrick 16 Upper Rear Firebrick 13 Lower Rear Firebrick 12 Left Side Firebrick 14 Right Side Firebrick Note CI1000HT does not have fire brick on...

Страница 34: ...ESSORIES Models CI1000HT CI2000HT PAGE 34 Catalog Model Description Stove Model H0459 WTK CI10 Window Trim Kit Charcoal CI1000HT H0455 WTK CI20 Window Trim Kit Charcoal CI2000HT Window Trim Kit CI1000...

Страница 35: ...LABEL SAFETY LISTING Model CI1000HT PAGE 35...

Страница 36: ...SAFETY LISTING LABEL Model CI2000HT PAGE 36...

Страница 37: ...EPA LABELS CI1000HT and CI2000HT PAGE 37...

Страница 38: ...38 OWNERSHIP RECORDS Dealer s Name Dealer s Address City State Zip Code Serial Number Date of Purchase Date Installed Notes SERVICE AND MAINTENANCE LOG Service Service Service Date Technician Descrip...

Страница 39: ......

Страница 40: ...venue Orange CA 92865 LENNOX reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinued colors styles and products Consult your lo...

Отзывы: