Burner Flame

CAUTION

To ensure proper operation, a licensed professional
service  technician (or equivalent) should check the
burner flame and conduct a combustion analysis
annually.

Electrical

 1 − Check all wiring for loose connections.
 2 − Check for the correct voltage at the furnace (furnace

operating).

 3 − Check amp−draw on the blower motor.

Motor Nameplate__________Actual__________

Service Reminder

Call your Lennox service technician if the unit will not oper-
ate. Before calling, always check the following to be sure
service is required:

 1 − Check that electrical disconnect switches are 

ON.

 2 − Check room thermostat for proper setting.
 3 − Replace any blown fuses or reset circuit breakers.
 4 − Gas valve should be 

ON

.

 5 − Air filter should not be plugged, which will limit air flow.
 6 − Is gas turned on at meter?
 7 − Is manual main shut−off valve open?
Record the model and serial number of the furnace. These
numbers are on the unit nameplate, which is located on the
blower deck below the combustion air inducer.

Serial Number

__________________

Model Number __________________

Safety Precautions

If you discover any of the following, shut down your
unit, and contact a Lennox dealer for an inspection by
a licensed professional service technician (or equiva-
lent).

D

If you repeatedly hear any new or unfamiliar sounds
while your unit is operating, there may be a problem. For
example, poorly performing burners can produce unfa-
miliar noises.

D

If you smell any unusual odors, your unit may be operat-
ing improperly. For example, units can give off unfamil-
iar odors if components are required to operate in ab-
normal conditions.

D

Look for visible signs of a malfunctioning unit. Examples
include unusual amounts of condensate on windows in-
side your house, visibly burnt components or unusual
dirt or rust accumulations on the vent pipe or in the unit.

D

If you experience headache, nausea, fatigue, or dizzi-
ness, the cause could be exposure to carbon monoxide
gas. This is often misdiagnosed as the flu because
symptoms are similar. If you suffer from flu−like symp-
toms that are exaggerated at home, but seem to sub-
side while you are away from the house, exposure to
carbon monoxide could be the cause.

Your vigilance may pay off in early detection of a problem
before either personal injury or property damage occurs.
Do not hesitate to contact a licensed professional service
technician (or equivalent) as an investment in your well be-
ing.

Planned Service

You should expect a service technician to check the follow-
ing items during an annual inspection. Power to the unit
must be shut off for the service technician’s safety.

Fresh air grilles and louvers

 (on the unit and in the room

where the furnace is installed) − Must be open and unob-
structed to provide combustion air.

Burners 

− Must be inspected for rust, dirt, or signs of water.

Vent pipe

 − Must be inspected for signs of water, damaged

or sagging pipe, or disconnected joints.

Unit appearance

 − Must be inspected for rust, dirt, signs

of water, burnt or damaged wires, or components.

Blower access door

 − Must be properly in place and pro-

vide a seal between the return air and the room where the

furnace is installed.

Return air duct 

− Must be properly attached and provide

an air seal to the unit.

Operating performance

 − Unit must be observed during

operation to monitor proper performance of the unit and the

vent system.

Combustion gases

 − Flue products must be analyzed and

compared to the unit specifications.

Problems detected during the inspection may make it nec-

essary to temporarily shut down the furnace until the items

can be repaired or replaced.

Pay attention to your furnace.

 Situations can arise be-

tween annual furnace inspections that may result in unsafe

operation.

Содержание SLP98UH SERIES

Страница 1: ...lier D Do not try to light any appliance D Do not touch any electrical switch do not use any phone in your building D Immediately call your gas supplier from a neighbor s phone Follow the gas supplier...

Страница 2: ...ore of these devices is activated furnace operation will stop If your home is left unattended for an extended period of time equipment op eration must be checked periodically If this is not possible t...

Страница 3: ...ice agency or the gas supplier Safety Instructions 1 Keep the furnace area clear and free of combustible material gasoline and other flammable vapors and liquids If it is installed in an insulated are...

Страница 4: ...tructions exactly a fire or explosion may result causing property damage personal injury or death BEFORE PLACING THE UNIT INTO OPERATION smell all around the appliance area for gas Be sure to smell ne...

Страница 5: ...vicing controls label all wires prior to dis connecting Take care to reconnect wires correctly Verify proper operation after servicing Venting System WARNING Asphyxiation Hazard The exhaust vent for t...

Страница 6: ...rnt components or unusual dirt or rust accumulations on the vent pipe or in the unit D If you experience headache nausea fatigue or dizzi ness the cause could be exposure to carbon monoxide gas This i...

Страница 7: ...r equivalent a service agency or the gas supplier Cabinet Parts Outer access panel Blower access panel Top cap Control Panel Parts Transformer SureLight integrated control Door interlock switch Circui...

Отзывы: