4
SETTING THE TIMER
Mo (Monday)
Tu (Tuesday)
We (Wednesday)
Th (Thursday)
Fr (Friday)
Sa (Saturday)
Su (Sunday)
Our electronic climate control with timer operation is a programmable terminal.
With this terminal you can program the unit to stop and start on each of the 7 days of the week.
The ON TIMER and OFF TIMER functions may be combined.
To set the timer, follow the instructions given below:
With the
button, select the
day of the week that you wish
to program. Any previous
settings will be displayed.
DAY
Push the
button to finish the
programming for that day and to
program a different day.
DAY
Push or wait 15 seconds
for the programming to be
accepted, after which the
symbol will remain visible and
the clock will show the real time.
ON TIMER
TIMER ACTIVE
Push the
button.
Push the
button and select the day of the week that you wish to delete from the settings.
Push the
button as many times as necessary until
- : - -
appears, showing that the setting for that day has
been deleted.
HOUR
DAY
ON TIMER
NOTE:
If the
symbol does not remain visible on the screen, the control has not stored the settings.
TIMER ACTIVE
Press the button.
The and
symbols
will flash on the screen.
ON TIMER
SET TIMER
With the
button, select the
day of the week that you wish
to program. Any previous
settings will be displayed.
DAY
Push the
button to finish the
programming for that day and to
program a different day.
DAY
Push or wait 15 seconds
for the programming to be
accepted, after which the
symbol will remain visible and
the clock will show the real time.
TIMER ACTIVE
OFF TIMER
Press the button.
The and
symbols
will flash on the screen.
SET TIMER
OFF TIMER
HOW TO DEACTIVATE THE ON TIMER / OFF TIMER FUNCTION
HOLD
TIMER ACTIVE
To deactivate the settings and store them for future use:
Press the
button for 3 seconds, until the
indication disappears.
To activate them once again, press the
button for 3 seconds once again, until the
indication appears
HOLD
TIMER ACTIVE
With the ON TIMER function, the unit will automatically
start at the selected time, in the same operating mode
as when it was switched off.
HOW TO DELETE THE ON TIMER / OFF TIMER FUNCTION
1
3
4
2
1
3
4
2
PROGRAMMING THE UNIT TO START
(ON TIMER)
PROGRAMMING THE UNIT TO STOP
(OFF TIMER)
HOUR
MINUTE
TIMER ACTIVE
With the
and
buttons,
enter the exact time at which you
wish the unit to start. The
symbol will flash.
HOUR
MINUTE
TIMER ACTIVE
With the
and
buttons,
enter the exact time at which you
wish the unit to stop. The