1.5. Indoor Unit Wall Mounts
MWCA009S4
Right Rear Hole
2-1/2 in. (64 mm)
diameter
Left Rear Hole
2-1/2 in. (64 mm)
diameter
Wall-Mount
Unit Outline
1-1/2 (38)
2 (51)
13-3/4 (349)
7 (178)
5-3/8
(136)
28-1/2 (724)
4
(102)
11
-3/8 (289)
1-7/8
(48)
Figure 2. 9K Indoor Unit Wall Plate Dimensions -
Inches (mm)
MWCA012S4
Right Rear Hole
2-1/2 in. (64 mm)
diameter
Left Rear Hole
2-1/2 in. (64 mm)
diameter
Wall-Mount
Unit Outline
1-3/4 (44)
1-3/4 (44)
16-3/4 (425)
9-1/8 (232)
5
(127)
31-5/8 (803)
7-1/2
(191)
11
-3/4 (298)
1-3/4
(44)
Figure 3. 12K Indoor Unit Wall Plate Dimensions -
Inches (mm)
MWCA018S4
Left Rear Hole
2-1/2 in. (64 mm)
diameter
Right Rear Hole
2-1/2 in. (64 mm)
diameter
20-3/8 (518)
5-5/8
(143)
Wall-Mount
Unit Outline
2-1/4 (57)
38 (965)
12-1/2 (318)
2-1/4
(57)
5-3/8 (137)
6-3/4 (171)
2-3/8 (60)
Figure 4. 18K Indoor Unit Wall Plate Dimensions -
Inches (mm)
MWCA024S4
Left Rear Hole
2-1/2 in. (64 mm)
diameter
Right Rear Hole
2-1/2 in. (64 mm)
diameter
21-3/4 (553)
11-7/8
(301)
Wall-Mount
Unit Outline
2-1/8 (54)
42-1/2 (1080)
13-1/4 (337)
1-7/8
(48)
6-7/8 (175)
8-5/8 (219)
1-7/8 (48)
Figure 5. 24K Indoor Unit Wall Plate Dimensions -
Inches (mm)
1.6. Indoor/Outdoor Matches
Indoor Unit Type
Outdoor Unit
Indoor Unit
Cooling
Capacity SEER
EER
Heat Capacity
HSPF
(IV)
AHRI
Reference
High
Low
Wall-Mounted Non-
Ducted
MHA009S4S-1L
MWHA009S4-1L
9000
19
11.5
10,000
6000
10
204014488
MHA009S4S-1P
MWHA009S4-1P
9000
18
11
9000
6000
9.5
204014490
MHA012S4S-1L
MWHA012S4-1L
12,000
19
10.5
12,000
7500
9.5
204014489
MHA012S4S-1P
MWHA012S4-1P
12,000
19
11
12,000
6800
9.5
204014491
MHA018S4S-1P
MWHA018S4-1P
18,000
19
11
18,000
11,000
10
204014492
MHA024S4S-1P
MWHA024S4-1P
24,000
17
9.5
24,000
14,400
9.5
204014493
•
Ratings are AHRI certified to AHRI Standard 210/240;
•
Cooling Ratings - 80°F dry bulb/67°F wet bulb entering indoor coil air and 95°F wet bulb/75°F dry bulb outdoor air temperature.
•
High Temperature Heating Ratings - 70°F dry bulb/60°F wet bulb entering indoor coil air and 47°F dry bulb/43°F wet bulb outdoor air temperature.
•
Low Temperature Heating Ratings - 70°F dry bulb/60°F wet bulb entering indoor coil air and 17°F dry bulb/15°F wet bulb outdoor air temperature.
•
To convert HSPF from Region IV to Region V - Divide by 1.15.