background image

18

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

LENNOX HEARTH PRODUCTS  •  MERIT PLUS

®

 DIRECT VENT GAS FIREPLACES (MPDP35/40)  •  CARE AND OPERATION INSTRUCTIONS

LENNOX HEARTH PRODUCTS

1508 Elm Hill Pike, Suite 108 

Nashville, TN 37210

visit us at www.Lennox.com

1-800-655-2008

PRODUCT REFERENCE INFORMATION

We recommend that you record the important  

reference information about your fireplace in 

the space provided below. 
Please  call  Lennox  Hearth  Products  for  the 

phone number of your nearest Lennox Hearth 

Products dealer who will answer your questions 

or address your concerns.

When ordering repair parts always provide:

1.

 The model number of the appliance.

2.

 The serial number of the appliance.

3.

 The part number.

4.

 The description of the part.

5.

 The quantity required.

6.

 The installation date of the appliance.

If  you  encounter  any  problems  or  have  any 

questions  concerning  the  installation  or  ap-

plication of this system, please contact your 

dealer or distributor.

REPLACEMENT PARTS

A  complete  parts  list  is  found  at  the  end  of 

this manual. Use only parts supplied from the 

manufacturer.

With proper care and maintenance, your appli-

ance will provide many years of enjoyment. If 

you should experience any problem, first refer 

to the troubleshooting guide in this manual. If 

problem persists, contact your Lennox Hearth 

Products dealer or distributor.

Normally, all parts should be ordered through 

your Lennox Hearth Products distributor or dealer.
Parts  will  be  shipped  at  prevailing  prices  at 

time of order.

WIRING DIAGRAM

Wiring diagrams are provided here for reference 

purposes only.  This information is also provided 

on schematics attached directly to the appliance 

on a pullout panel located within the control 

compartment.

CAUTION: LABEL ALL WIRES PRIOR TO 

DISCONNECTION WHEN SERVICING 

CONTROLS.  WIRING  ERRORS  CAN 

CAUSE IMPROPER AND DANGEROUS 

APPLIANCE OPERATION.

ATTENTION:  AU  MOMENT  DE 

L'ENTRETIEN  DES  COMMANDES, 

ÉTIQUETEZ TOUS LES FILS AVANT DE 

LES DÉBRANCHER. DES ERREURS DE 

CÁBLAGE PEU-VENT ENTRAÎNER UN 

FONCTIONNEMENT  INADÉQUAT  ET 

DANGEREUX.

Fireplace Model Number  ________________________________________________

Fireplace Serial Number _________________________________________________

Date Installed _________________________________________________________

Type of Gas Used in Fireplace  ____________________________________________

Dealer Name  _________________________________________________________

Figure 17

DFC WIRE HARNESS

PROFLAME DFC BOARD

UNIT MOUNTED

ROCKER SWITCH*

PILOT TUBE

FAN

POWER CORD

POWER CORD

CABLE HARNESS

HIGH-TEMP SLEEVE

FAN CONTROL

MODULE

WALL

RECEIVER

DIGIT

AL

FIREPLACE BURNER CONTROL

SPARK WIRE 

CABLE

PILOT SENSOR 

CABLE

IGNITER ROD

FLAME

SENSOR

PROFLAME

ELECTRONIC

VALVE

JUNCTION BOX

* Unit Mounted Rocker Switch

OFF (o) = Intermittent Pilot Mode

ON   (-) = Standing Pilot Mode

Y

120V 

Out

Fan

Power

Aux

Out

B

W G

C

A

V

 

0

2

1

Schematic Representation Only

PILOT BURNER

IGNITER-SENSOR

ASSEMBLY

B

B

Wiring Color Code

B = Black

BL = Blue

BR = Brown

G = Green

GY = Gray

O= Orange

PU = Purple

W = White

R = Red

P = Pink

Y = Yellow

O

W

W

W

Y

G

G

G

G

B, BR, Y

, O

P, BL

P, BL

R,PU,GY

NOTES:

1. If any of the original wire as supplied must be re-

placed, use Type AWM 105°C - 18 gage wire ONLY.

2. 120 VAC, 60 Hz - Less than 5 Amps. 

CAUTION: label all wires prior to disconnection 

when servicing controls. Wiring errors can cause 

improper and dangerous operation. Verify proper 

operation after servicing.

ELECTRONIC 

IGNITION WIRING 

DIAGRAM

*Unit Mounted CPI Rocker Switch

Содержание MPDP35IN

Страница 1: ...SSEMENT AVISO HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS UNE SURFACE VITR E CHAUDE PEUT CAUSER DES BR LURES LAISSER REFROIDIR LA SURFACE VITR E AVAN...

Страница 2: ...Notices 6 Appliance Operation Notices 6 Warranty Information 6 General Information 6 BTU Input 7 Gas Pressure Requirements 7 Orifice Sizes 7 Burn In Period 7 Operation Care of Your Appliance 8 Gas Con...

Страница 3: ...sez la section Informations importantes relatives la s curit page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica para evit...

Страница 4: ...vent subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer o...

Страница 5: ...iquette sur la surface de la plaque du r cepteur mural qui contr le le foyer Figure A Choisissez la langue qui est principalement parl e dans la r sidence du propri taire 2 Rep rezlat l commandeetnett...

Страница 6: ...ith other gases unless a certified kit is used Cet appareil doit tre utilis uniquement avec les types de gaz indiqu s sur la plaque signal tique Ne pas l utiliser avec d autres gaz sauf si un kit de c...

Страница 7: ...meters abovesealevelusingthestandardburner orifice sizes marked with an in Table 4 For elevations above 4500 feet contact your gas supplier or qualified service technician Deration At higher elevation...

Страница 8: ...risque d avoir acc s la pi ce et aux surfaces chaudes Figure 2 Remote Control System The Remote and Receiver allows you to com mand the functions of your fireplace from the comfortofyourchair Itisconf...

Страница 9: ...y Power Detection The life span of the Receiver batteries depends onvariousfactors qualityofthebatteriesused the number of ignitions of the appliance the number of changes to the room thermostat set p...

Страница 10: ...s the Thermostat Key The LCD display on the Transmitter will change to show that the room temperature is ON and the set temperature is now displayed see Figure 7 To adjust the set temperature press th...

Страница 11: ...and at least annually by a qualified service techni cian inspection should include ensuring that exhaust or intake passages are unobstructed and vent components are properly assembled and not damaged...

Страница 12: ...panel should not be re moved except to gain access to the components within the firebox Removing the Glass Enclosure Panel Remove the top radiant panel assembly To access the two glass door securing...

Страница 13: ...d with these notches directly against the grate Handle logs carefully to prevent breakage Proper log placement is critical to encourage outstanding flame appearance and prevent sooting When positioned...

Страница 14: ...n the order shown Position the rear log on the brackets at the rear of the firebox with the log s notches directly over the brackets Position the right log log no 3 by inserting the pin from the rear...

Страница 15: ...ual logs as shown below Logs should be placed in the order shown Position the center log on the burner first then place the glowing embers as shown in Figure 10 Place the rear log both the right and l...

Страница 16: ...e adjusted between these two extremes Air Shutter Adjustment Guidelines If there is smoke or soot present first check the log set positioning to ensure that the flames are not impinging on any of the...

Страница 17: ...burner to operate for at least 15 minutes while observing the flame continu ously to ensure that the proper flame ap pearancehasbeenachieved Ifthefollowing conditions are present adjust accordingly If...

Страница 18: ...icsattacheddirectlytotheappliance on a pullout panel located within the control compartment CAUTION Labelallwirespriorto disconnection when servicing controls Wiring errors can causeimproperanddangero...

Страница 19: ...affixes directly to the front glass enclosure panel Termination Guard Kits all models Cat No Model No Description H5820 4 5HTSK Termination Shroud 87L02 SV4 5HGS Termination Guard Deluxe Deluxe Termin...

Страница 20: ...nal twin pane doors ARCH DESIGN KITS Cat No Model Description Model Series H8769 AD35B 2 35 Arch Doors Black MPDP35 H8770 AD35SP 2 35 Arch Doors Satin Pewter H8771 AD40B 2 40 Arch Doors Black MPDP40 H...

Страница 21: ...and at the base within the firebox for signs of blockage or obstruction Look for any signs of dislocation or deteriorationoftheventcomponents reconnectorreplaceasnecessary Appliance Checkout Qualified...

Страница 22: ...e tools Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the applianc...

Страница 23: ...ivante 8 Mettez l appareil sous tension 9 Placez l interrupteur du r cepteur en position REMOTE 10 Appuyez sur le bouton ON OFF pour s lectionner ON 11 Ajustez le thermostat sur la t l commande l ajus...

Страница 24: ...atteries behind the wall plate Checkbuildingcircuitbreakerstoensurepower is on to the fireplace 2 The main burner does not light and the igniter is sparking A Gas is not reaching the fireplace Check t...

Страница 25: ...27K30 1 27K30 1 16 Forced Air Blower FBK 100 80L84 1 80L84 1 WARNING Failure to position the parts in accordance with these diagrams orfailuretouseonlypartsspecifi callyapprovedwiththisappliance may r...

Страница 26: ...TH PRODUCTS MERIT PLUS DIRECT VENT GAS FIREPLACES MPDP35 40 CARE AND OPERATION INSTRUCTIONS Replacement Parts 1 7 6 3 4 5 12 13 11 2 9 8 8 9 10 10 MPDP35 MPDP35 MPDP40 MPDP40 MPDP40 MPDP35 19 16 FBK 2...

Страница 27: ...27 LENNOX HEARTH PRODUCTS MERIT PLUS DIRECT VENT GAS FIREPLACES MPDP35 40 CARE AND OPERATION INSTRUCTIONS NOTES...

Страница 28: ...ennox Hearth Products reserves the right to make changes at any time without notice in design materials specifications and prices and also to discontinue colors styles and products Consult your local...

Отзывы: