Filters

All ML180UHE filters are installed external to the unit. Fil

-

ters  should  be  inspected  monthly.  Clean  or  replace  the 

filter( s) when necessary to ensure proper furnace opera

-

tion. 

A filter must be in place when the unit is operat

-

ing.

 See table 1 for recommended filter sizes.

NOTE - 

Use  replacement  filters  that  are  similar  in  size 

and efficiency ratings to those originally provided by the 

installing contractor. Use of replacement filters with higher 

filtration ratings may restrict air flow to the furnace. This 

may result in reduced unit efficiency, as well as premature 

blower motor failure.

TABLE 1

 

Furnace 

Cabinet Width

Filter Size

Side Return

Bottom Return

14-1/2”

16 X 25 X 1 (1)

14 X 25 X 1 (1)

17-1/2”

16 X 25 X 1 (1)

16 X 25 X 1 (1)

21”

16 X 25 X 1 (1)

20 X 25 X 1 (1)

24-1/2”

16 X 25 X 1 (2)

24 X 25 X 1 (1)

Maintenance

A licensed professional service technician (or equivalent) 

should inspect the complete system each season (heat

-

ing and cooling). The following maintenance procedures 

should only be conducted by a licensed professional ser

-

vice technician (or equivalent). 

Do not attempt to service 

the unit in any way.

 WARNING

ELECTRICAL SHOCK, FIRE,

OR EXPLOSION HAZARD.

Failure to follow safety warnings exactly could 

result in dangerous operation, serious injury, death 

or property damage. Improper servicing could result 

in dangerous operation, serious injury, death, or 

property damage. Before servicing, disconnect all 

electrical power to furnace.

When servicing controls, label all wires prior 

to disconnecting. Take care to reconnect wires 

correctly. Verify proper operation after servicing.

 CAUTION

To ensure proper operation, a licensed professional 

service technician (or equivalent) should check the 

burner  flame  and  conduct  a  combustion  analysis 

annually.

Annually (before heating season) inspect furnace venting 

system, vent cap, heat exchanger and burners for corro

-

sion, deterioration, or deposits of debris. Remove any ob

-

structions.

Inspect the furnace venting system to make sure it is in 

place, physically sound and without holes, corrosion, or 

blockage.  The  vent  connector  must  be  correctly  posi

-

tioned and sloped upward. The vent connector must be 

physically sound, without holes or excessive corrosion. 

Inspect the furnace return air duct connection. The duct 

must be sealed to the furnace and it must terminate out

-

side the space containing the furnace.
Inspect the physical support of the furnace to guarantee 

that it is sound. The support must not sag and must not 

have cracks or gaps around the base of the furnace. There 

must be a seal between the furnace base and the support.
During  a  seasonal  check,  the  service  technician  will  in

-

spect the indoor blower and the burner flames along with 

the venting system.

Blower

Check  blower  wheel  for  any  debris  and  clean  it,  if  nec

-

essary. The  blower  motor  is  pre-lubricated  for  extended 

bearing life. No further lubrication is needed.

 WARNING

The blower access panel must be securely in place 

when the blower and burners are operating. Gas 

fumes, which could contain carbon monoxide, can 

be drawn into living space resulting in personal 

injury or death.

Service Reminder

Call your Lennox service technician if the unit will not op-

erate.  Before  calling,  always  check  the  following  to  be 

sure service is required.

1 - 

 Check that electrical disconnect switches are 

ON

.

2 - 

 Check room thermostat for proper setting.

3 - 

  Replace any blown fuses or reset circuit breakers.

4 - 

 Gas valve should be

 ON

.

5 - 

 Air filter should not be plugged, which will limit air 

flow.

6 - 

 Is gas turned on at meter?

7 - 

Is manual main shut-off valve open?

Record the model and serial number of the furnace. These 

numbers are on the unit nameplate, which is located be

-

low the burners.
Serial Number ________________________________
Model Number ________________________________

Содержание ML180UHE

Страница 1: ...ings exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Installation and...

Страница 2: ...on will stop If your home is left unattended for an extended period of time equipment operation must be checked periodically If this is not possi ble the water supply to the house should be shut off a...

Страница 3: ...as pressure and gas flow rate adequate combustion air and proper venting WARNING Asphyxiation Hazard The exhaust vent for this furnace must be leak free and must be securely connected to the furnace f...

Страница 4: ...try to light the burners by hand 5 Remove the access panel 6 Move switch on gas valve to OFF Do not force See figure 2 7 Wait five minutes to clear out any gas If you then smell gas STOP Immediately c...

Страница 5: ...n inspect furnace venting system vent cap heat exchanger and burners for corro sion deterioration or deposits of debris Remove any ob structions Inspect the furnace venting system to make sure it is i...

Страница 6: ...or 2 Check the condition of the belt and shaft bearings if applicable 3 Inspect all gas pipe and connections for leaks 4 Check the cleanliness of filters and change if necessary monthly 5 Check the co...

Страница 7: ...innocently stored next to the furnace may obstruct the combustion air supply This could cause incomplete combustion and the produc tion of carbon monoxide gas Repair Parts List The following repair pa...

Отзывы: