background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

17

ACCESSORY COMPONENTS

Outside Air Kits Models FOAK-4 and 
FOAK-4LD

Outside Air kits are available with duct (FOAK-4) 
and without duct (FOAK-4LD) for use if outside 
combustion air is required or desired.  If model 
FOAK-4LD is used it must be used in conjunction 
with locally purchased, non-combustible Class 
1 or Class 0 fl exible duct.

Polished Brass and Brushed Stainless
Hood Kits

Attractive hoods are available in two styles to 
be used on the Multi-Open Series appliances. 
These hoods are designed to be fi tted to the glass 
viewing sides of the appliance. In addition to 
providing an aesthetically pleasing appearance 
to your appliance installation, the hood reduces 
heat effects to decorative mantles and fi nish 
materials located above the fi replace opening. 
The hood kit replaces the standard hood that 
comes with these appliances and snaps into 
place.  These kits can be retrofi tted to previously 
installed appliances.

* 35" Eyebrow Hood Kits

Cat. No.

Model No.

Description

96K67

EB35PB

Hood Kit, Polished
Brass

88L49

EB35BS

Hood Kit, Brushed 
Stainless

* These hood kits replace the standard hood that 
comes with these fi replaces.

(ref. Form #504,142M)

Arch Door Kits

Two types of arch door kits are available for 
the Multi-Open Series.  Both types of kits are 
easy to install and do not require hardware to 
attach them to the standard door frame. These 
kits can be retrofi tted to previously installed 
Multi-Open Series appliances. The decorative 
arch kits can not be used in conjunction with 
the screen panel kit.

* 35" Arch Door Kits

Cat. No.

Model No.

Description

26M43

ADK35CMPB

Arch Door, Polished Brass

26M44

ADK35CMBS

Arch Door, Brushed Stainless

(ref. Form # 750,021M)

Polished Brass and Brushed Stainless 
Louvers Kits

Decorative louvers are available for use with all 
Multi-Open Series appliances. These louvers 
are designed to replace the standard radiant 
panels that are provided with the appliance. 
These kits include a top 3-piece assembly and 
a bottom 3-piece assembly.  They provide a 
touch of elegance to any Multi-Open Series 
appliance.  These kits can be retrofi tted to 
previously installed appliances.

35" Assembled Louver Kits

Cat. No.

Model No.

Description

88L28

LVR35PB-2

Louver Kit, Polished 
Brass

88L32

LVR35BS-2

Louver Kit, Brushed 
Stainless

(ref. Form # 750,119M)

2-Piece Polished Brass and Brushed 
Stainless Louvers Kits

These louvers are designed to replace either 
the middle charcoal louver of each set or the 
charcoal louver in each set closest to the glass 
door. These kits include two narrow louvers.  
They provide a touch of elegance to these 
appliances.  These kits can be retrofi tted to 
previously installed appliances.

2-Piece Louver Kits

Cat. No.

Model No.

Description

96L05

2LVR35PB

2 Pc. Louver Kit,
Polished Brass

96L09

2LVR35BS

2 Pc. Louver Kit, 
Brushed Stainless

(ref. Form # 504,224M))

(ref. Form # 750,008M)

Outside Combustion Air Kits

Cat. No.

Model No.

Description

81L87

FOAK-4

Combustion Air Kit (with 
duct)

81L88

FOAK-4LD

Combustion Air Kit 
(without duct)

Содержание Merit Plus MPB35ST-NE

Страница 1: ...ot store or use gasoline or other flammables or liquids in the vicinity of this or any other appliance FOR YOUR SAFETY What to do if you smell gas DO NOT light any appliance DO NOT touch any electrica...

Страница 2: ...Electronic models have a fixed rate gas valve Input of electronic models is shown in the following table INTRODUCTION The millivolt appliances have a millivolt gas controlvalvewitha piezoignitionsyste...

Страница 3: ...ngappliance voiding its warranty Any change to this appliance and or its operating controlsisdangerous Improper installation or use of this appli ance can cause serious injury or deathfromfire burns e...

Страница 4: ...alve shown in Figure 3 Gas Control Compartment Access The gas controls can be found behind the control compartment access panel To open the control compartment access panel actuate the spring loaded m...

Страница 5: ...ng pilot flame Exercise cau tion when using products with combustible vapors VENT OPERATION TEST A vent operation test is required as part of the installationtoverifythatproperventingcondi tions exist...

Страница 6: ...d service technician should follow vent installation instructions for proper reassembly and proper sealing of the venting system components However more frequent periodic inspections and cleanings sho...

Страница 7: ...s properly installed Generally the glass enclosure panels should not be removed except to gain access to the components within the firebox and the appliance may only be operated without the front glas...

Страница 8: ...ulite Bag 2 liters F D Bottom View of Logs in packaging Top View of Logs C E A B Glowing Embers Bag of Glowing Embers rockwool Separate into Quarter Size separate Pieces Top View of Logs Installed E B...

Страница 9: ...tted Distribute these pieces over the surface of the burner as shown in Figure 8 Do not use more than is necessary Ensure that the main burner ports remain uncovered by the ember material Note This ap...

Страница 10: ...ar sooty Air Shutter Adjustment Guidelines Amount of Primary Air Flame Color Air Shutter Adjustment If air shutter is closed too far Flame will be orange Air shutter gap should be increased If air shu...

Страница 11: ...box Clean firebox walls and log grate Replace logs embers rockwool and vermiculite as detailed in this manual see Pagexs 8 10 Check Flame Patterns and Flame Height Homeowner Refer to Figurex 15 on Pag...

Страница 12: ...ual Reset Spill Switch has Tripped or is defective Follow Manual Reset procedure on Page 6 Once the redresetbuttonisfullydepressedandclicksin check continuity with a multimeter between switch terminal...

Страница 13: ...V common leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identify proper lead this check must be done with the valve control con nected and igniter powered NO Chec...

Страница 14: ..._____ The Date On Which Your Fireplace Was Installed___________________________ The Type of Gas Your Fireplace Uses ____________________________________ Your Dealer s Name ____________________________...

Страница 15: ...on near the fireplace WhiteWallSwitchKit Cat No ModelNo Description 85L87 FWSK OFF ONWallSwitchKit ref Form 750 127M Touch Up Paint Kit Repair of minor scratches and discoloration of theappliancecharc...

Страница 16: ...58 AD35C 35 Arch Doors Charcoal H0859 AD35TI 35 Arch Doors Textured Iron H0860 AD35SP 35 Arch Doors Satin Pewter H0861 AD35AB 35 Arch Doors Antique Brass Arch Pane Design Kits H0930 APD35C 35 Arch Pan...

Страница 17: ...to previously installed Multi Open Series appliances The decorative arch kits can not be used in conjunction with the screen panel kit 35 Arch Door Kits Cat No Model No Description 26M43 ADK35CMPB Arc...

Страница 18: ...AT TO DO IF YOU SMELL GAS Extinguish any open flame Open windows Do not light any appliance Do not touch any electrical switches TO TURN OFF GAS TO APPLIANCE 1 Turn remote wall switch OFF The pilot wi...

Страница 19: ...s been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRU...

Страница 20: ...l 11 H3358 1 Grate Assembly All 12 69L2101 4 Latch Glass Enclosure Panel All 13 H3354 1 Firebox Sub floor All Item Part Cat Qty Description Where Used Misc Replacement Parts 14 H3210 1 Log Set All 15...

Отзывы: