2.
3.
Installation of indoor unit
Make the power connection wire go
through the cable-cross hole at the back
of indoor unit and then pull it out from
the front side.
4.
5.
Remove the wire clip; connect the power connection wire to the wiring terminal
according to the color; tighten the screw and then fix the power connection wire
with wire clip.
Close the panel.
●
cable-cross
hole
power connection
Note: the wiring board is for reference only, please refer to the actual one.
Put wiring cover back and then tighten the screw.
wire
Note:
●
installation.
For the air conditioner without plug, an air switch must be installed in the line.
The air switch should be all-pole parting and the contact parting distance should
be more than 3mm.
All wires of indoor unit and outdoor unit should be connected by a professional.
for a new one. Avoid extending the wire by yourself.
12K Heat pump type:
N(1) 2
green
Outdoor unit connection
Outdoor unit connection
blue black yellow-
orange
violet
black
blue
yellow-
green
N(1) 2
4 5
12
、
18K Cool only type:
24K Cool only type:
N(1) 2 3
brown yellow-
green
blue black
Outdoor unit connection
24K Heat pump type:
Outdoor unit connection
yellow-
green
brown violet orange
N(1)
blue black
2
3
4
5