Installation of indoor unit
Step one: choosing installation location
rm it with the client.
Step two: install wall-mounting frame
1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the
3.
Step three: open piping hole
1.
Mark in the middle of it
Level meter
Mark in the middle of it
Level meter
2. Open a piping hole with the diameter of Φ55 or Φ70 on the selected outlet
pipe position.In order to drain smoothly, slant the piping hole on the wall
slightly downward to the outdoor side with the gradient of 5-10°.
25
Choose the position of piping hole according to the direction of outlet pipe. The
position of piping hole should be a little lower than the wall-mounted frame,
shown as below.
18K
、
24K
;
Wall
Wall
Space
to the
wall
above
150mm
Right
Φ55mm
Rear piping hole
Wall
Space
to the
wall
above
150mm
Right
Φ55/Φ70mm
Rear piping hole
Space
to the
wall
above
150mm
Left
Φ55mm
Rear piping hole
Space
to the
wall
above
150mm
Left
Φ55/Φ70mm
Rear piping hole
12K:
Wall
plastic expansion particles in the holes.
Fix the wall-mounting frame on the wall with tapping screws (ST4.2X25TA) and
.