9
Technical Information
Service Manual
2.2 Operation Characteristic Curve
g
n
il
o
o
C
Outdoor temp.(°C)
g
n
it
a
e
H
Capacity ratio(
%)
Outdoor temp.(°C)
0
20
40
60
80
100
120
140
-13
-4
5
14
23
32
41 50 59 68 75.2
95
97
99
101 103 105
107 109
115
104 111 113
100
105
95
90
85
80
75
70
65
60
55
50
Outdoor temp.(°F)
Capacity ratio (%
)
Conditions
Indoor:DB
80°F
/WB66.9
°F
Outdoor:DB95°F
Indoor air flow:Super High
Pipe length:
24.6ft
Conditions
Indoor:DB
80°F
/WB66.9
°F
Outdoor:DB95°F
Indoor air flow:Super High
Pipe length:
24.6ft
2.3 Cooling and Heating Data Sheet in Rated Frequency
Rated cooling
condition(°F) (DB/WB)
Model
Pressure of gas pipe
connecting indoor
and outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
revolution
(Hz)
Indoor
Outdoor
PSIG
T1 (°F)
T2 (°F)
81/66
95/75
09/12K
123.2~145
in:46~52
out:52~57
in:122~176
out:99~109
Suprt High
High
58
81/66
95/75
18/24K
130~142
in:46.4~51.8
out:51.8~57.2
in:167~181.4
out:98.6~118.4 Super High
High
75
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 24.6ft.
Cooling: