Page 11
Troubleshooting
CAUTIONS
If one of the following conditions occurs, switch off the power supply immediately and contact
your dealer for further assistance.
•
The operation light continues to flash rapidly after the unit has been restarted.
•
The remote control buttons do not work.
•
The unit continually trips fuses or circuit breakers.
•
A foreign object or water enters the air conditioner.
•
Other abnormal situations.
•
The indoor unit leaks.
Common Problems
The following symptoms are not a malfunction and in most situations will not require repairs.
Problem
Possible Causes
Unit does not
turn on when
pressing ON/
OFF button
The unit has a 3-minute protection feature that prevents the unit from
overloading. The unit cannot be restarted within three minutes of being
turned off.
Cooling and Heating Models: If the Operation light and PRE-DEF (Pre-heating/
Defrost) indicators are lit up, the outdoor temperature is too cold and the unit’s
anti-cold wind is activated in order to defrost the unit.
In Cooling-only Models: If the “Fan Only” indicator is lit up, the outdoor
temperature is too cold and the unit’s anti-freeze protection is activated in
order to defrost the unit.
The unit changes
from COOL mode
to FAN mode
The unit changes its setting to prevent frost from forming on the unit. Once
the temperature increases, the unit will start operating again.
The set temperature has been reached, at which point the unit turns off the
compressor. The unit will resume operating when the temperature fluctuates
again.
The indoor unit
emits white mist
In humid regions, a large temperature difference between the room’s air and
the conditioned air can cause white mist.
Both the indoor
and outdoor units
emit white mist
When the unit restarts in HEAT mode after defrosting, white mist may be
emitted due to moisture generated from the defrosting process.
The indoor unit
makes noises
A squeaking sound is heard when the system is OFF or in COOL mode. The
noise is also heard when the drain pump (optional) is in operation.
A squeaking sound may occur after running the unit in HEAT mode due to
expansion and contraction of the unit’s plastic parts.
Both the indoor
unit and outdoor
unit make noises
A low hissing sound may occur during operation. This is normal and is caused
by refrigerant gas flowing through both the indoor and outdoor units.
A low hissing sound may be heard when the system starts, has just stopped
running or is defrosting. This noise is normal and is caused by the refrigerant
gas stopping or changing direction.
The outdoor unit
makes noises
The unit will make different sounds based on its current operating mode.
Troubleshooting
5