background image

TROUBLESHOOTING    

Qualified Technicians Only

 

 

PAGE 24 

(MODEL L20 BF-2 ONLY) 

 
SPILL SWITCH 

This appliance is equipped with a 

“Spill Switch”

 which is a 

safety device that will shut off gas to the burner in case of sus-
tained back draft or flue gas spillage from the draft hood.  The 
purpose of this safety device is to prevent potentially harmful 
gases from entering your home in the event of a blockage in the 
vent system.  Once the switch has been activated, the burner 
cannot be relit until the switch is reset manually (see 

Accessing 

and Resetting Spill Switch

 on this page).  Repeated tripping of 

the switch may indicate there is an obstruction in the venting 
system.  Other possible causes for the spill switch tripping are 
listed below (ordered from most likely to least likely). Note: En-
sure that appliance is cold before performing any checks. 
 

Troubleshooting Check List (Qualified Technicians Only) 

 

Flue Blockage - Check venting system for blockage (e.g. bird 
nest, damage, etc.). 

 

Down draft (Is a high wind termination cap installed?). 

 

Examine entire venting system for faults such as discon-
nected joints or damaged vent sections. 

 

Check the vent sizing according to specifications, and vent 
configurations (correct venting system, if necessary). 

 

Inadequate make-up air supply in the dwelling, resulting in 
negative pressure, inhibiting exhaust flow of the appliance. 
(evaluate and determine ways to increase make-up air, if nec-
essary, within the area of the installation). 

 

Defective spill switch (very rare) - Disconnect wires from 

Spill 

Switch

.  Set Multimeter on ohms and do an ohm check between 

terminals on switch.   A “O” ohms reading indicates a good switch. 
An infinite ohms of “1” reading indicates a defective (or open) 
switch.

 

 

 
If spillage is suspected, a simple spillage test can be conducted 
to confirm or out rule a spillage condition (see 

Spillage Test

 on 

this page). 
 

ACCESSING AND RESETTING SPILL SWITCH 

1. 

UNPLUG BLOWER POWER CORD.

 

2.  Using a ¼” nut driver, remove 

Rear Access Panel

 (see Fig. 1). 

 

 

 
3.  Locate 

Spill Switch

 and press the red button in the center of 

the switch (press in firmly until button stays depressed). See 
Fig. 2, 3 & 4. 

4.  Perform Spillage Test prior to reinstalling 

Rear Access Panel

 

(see 

Spillage Test Procedure 

on this page).  

 

 

 

 

 

 

 

 
SPILLAGE TEST PROCEDURE 

A flue spillage test is recommended as part of the installation 
and periodically afterwards.   

 
1. Remove 

Rear Access Panel

, if necessary (Fig. 1).  

2.  Close all the doors and windows in the room.  Turn ON all 

exhaust fans in the home. 

3.  Light the appliance. Adjust burner flame to highest setting 

and operate for approximately 10 minutes before checking 
for spillage.   

4.  Use an open flame (preferably a wooden match) or smoke 

(cigarette, burning rope) to determine if spillage is present.  
To test for spillage, move the flame or smoke device across 
the opening at the bottom of the draft hood as shown be-
low.  If the flame or smoke is drawn into the opening, there 
is no spillage.  If the flame or smoke is blown out or away 
from the opening, spillage is present and corrective action 
should be taken before operating the appliance (see bullets 
under 

Spill Switch 

on this page).   

 

 

 

 
5. Reinstall 

Rear Access Panel

 (see Fig. 1).

Spill Switch 

Flame drawn 
in, indicates 
no spillage

 

 

Fig. 3

Press In This  
Red Reset Button

 

Draft Hood 

Stove  Back 

Fig. 4

Spill Switch

Draft Hood

Remove screws 

indicated by arrows

Stove Back 

Rear Access 

Panel 

Fig. 1 

Spill Switch

Fig. 2

Reset Button 

Содержание L20 BF-2

Страница 1: ...ed call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier AVERTISSEMENT ASSUREZ VOUS DE BIEN SUIVRE LES INSTRUCTIONS DONN DANS...

Страница 2: ...SIDENTIAL LINE VOLT AGE TO THE GAS CONTROL VALVE OR CONTROL WIRING SYSTEM OF THE UNIT 9 ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVIC ING MUST BE REPLACED PRIOR TO OPERATING THE AP PLIANCE 10 WARNING...

Страница 3: ...e 11 CONGRATULATIONS ON THE PURCHASE OF YOUR NEW GAS APPLIANCE MANUFACTURED BY LENNOX HEARTH PROD UCTS When you purchased your new gas fired heater you joined the ranks of thousands of concerned indiv...

Страница 4: ...of appliance deration replacing burner orifice with a smaller one to reduce input Ratings must be reduced at the rate of 4 percent for each 1 000 feet above sea level Refer to for USA NFPA 54 ANSI Z2...

Страница 5: ...e 2 Local amendments 3 Recognized testing lab CSA AGA 4 Is a permit required cost 5 In some states or municipalities a licensed gas fitter or plumber may be required to install this appliance Check wi...

Страница 6: ...aftermarket permanently located manufactured home where not prohibited by local codes When installed in Manufactured Housing the following supplemental requirements must be met The appliance must be...

Страница 7: ...al vent installation requirements Horizontal vent clearances 3 minimum top 1 minimum on bottom and sidewalls Vertical vent clearances 1 minimum Install vent support brackets every 4 feet of vertical p...

Страница 8: ...j BlackPipeLength N A N A SV0E45 45Elbow Galvalume 945 45Elbow Galvanized SV0EB45 45Elbow Black 945B 45Elbow Black SV0E90 90Elbow GalvalumeSwivel 990G 90Elbow GalvanizedSwivel SV0EB90 90Elbow BlackSwi...

Страница 9: ...Factory Built Chimney Conversion Kit B for 6 7 8 I D Only compatible w specific brands Contact Vent Manufacturer SV4CCK3 Factory Built Chimney Conversion Kit for 10 I D 1 insulation 7 I D 2 insulatio...

Страница 10: ...meter regulator assembly within 3 feet 90 cm horizontally from the centerline of the regulator I 3 ft USA Clearance to service regulator vent outlet 6 ft CAN J 9 USA Clearance to non mechanical air s...

Страница 11: ...ping and components Refer to the pipe manufacturer s installation instructions for specific requirements for their product Maintain proper clearances to combustible materials as specified by the pipe...

Страница 12: ...valve must be installed up stream of any connector so that the appliance may be isolated to allow service removal and replacement within six feet of the appliance per NFPA 54 or twelve inches in some...

Страница 13: ...g the latching rod in the rod guide Care should be exercised to not adjust the tension too high If glass door removal is required for replacement or mainte nance the door can be removed in the open po...

Страница 14: ...pins and mounts provided This will en sure a proper flame and safe combustion 1 Carefully place the largest log in the rear of the firebox as shown in the following illustration 2 Install the front lo...

Страница 15: ...essary for the desired flame characteristics see Burner Flame Appearance page 21 To adjust air shutter 1 Remove burner from firebox by removing the 2 nuts as shown in the following picture Then lift b...

Страница 16: ...the floor If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 6 Visually locate the pilot located in the center of the firebox benea...

Страница 17: ...a relief door in case of delayed ignition blowback If the relief door opens remove back panel and inspect for gasket damage If necessary replace with fac tory supplied gasket only Confirm relief door...

Страница 18: ...n est pas propre et compl te jusqu l op ration de l appareil converti est ch que suivant les crit res tablis dans les instructions de propri taire provisionn es avec l quipement IN CANADA The convers...

Страница 19: ...t inlet 1 2 NPT fitting using the fitting required 11 Perform leak Test CAUTION After this procedure is complete with appli ance installed and connected to gas line recheck the pilot connection and ma...

Страница 20: ...t air intake system is disassembled for any reason the service technician should follow vent manu factures instructions for proper reassembly and sealing of the vent air intake system IMPORTANT APPLIA...

Страница 21: ...nce or behavior as outlined here consult a qualified gas appliance technician A proper burner flame is shown above The burner flame should have the following characteristics after initial start up let...

Страница 22: ...ating system components for repair replacement Note If replacement of any of the original wire is necessary use 105 C thermoplastic wiring MODEL L20 BF 2 MODEL L20 DVF 2 CIRCULATING BLOWER WIRING DIAG...

Страница 23: ...en shuts off pilot flame remains lit a Flue vent is blocked flue gas is spilling which activates the safety switch and shuts down the appliance b B Vent The house is negatively pressurized Examine ven...

Страница 24: ...switch A O ohms reading indicates a good switch An infinite ohms of 1 reading indicates a defective or open switch If spillage is suspected a simple spillage test can be conducted to confirm or out ru...

Страница 25: ...L37 Blower Air Circulating All 3 52L12 Thermal Fan Switch All 4 34121H Disc High Limit Manual Reset Spill Switch L250 30F L20 BF 2 5 10050088 Rheostat speed control for blower All 6 12058820 Power Cor...

Страница 26: ...or Kit L20 Gold 2 14M05 BRK L20 Brickaded Interior Kit L20 3 H0251 RC STAT Deluxe Remote Control Thermostatically controlled 4 H0249 RC RC Remote Control Standard On Off 5 89L36 WTK Wall Thermostat Ki...

Страница 27: ...Side View SPECIFICATIONS GAS TYPE NATURAL GAS PROPANE LP CLEARANCES TO COMBUSTIBLES Orifice Size 40 098 53 0595 Back Wall Min 2 In 51 mm Minimum Supply Pressure 4 5 WC 10 5 WC Side Wall Min 12 In 305...

Страница 28: ...y Top View Side View SPECIFICATIONS GAS TYPE NATURAL GAS PROPANE LP MINIMUM CLEARANCES TO COMBUSTIBLES Orifice Size 40 098 53 0595 Back Wall Min 2 In 51 mm Minimum Supply Pressure 4 5 WC 10 5 WC Side...

Страница 29: ...SAFETY LISTING LABEL RATING PLATE PAGE 29...

Страница 30: ...SAFETY LISTING LABEL RATING PLATE PAGE 30...

Страница 31: ...31 OWNERSHIP RECORDS Dealer s Name Dealer s Address City State Zip Code Serial Number Date of Purchase Date Installed Notes SERVICE AND MAINTENANCE LOG Service Service Service Date Technician Descrip...

Страница 32: ...venue Orange CA 92865 LENNOX reserves the right to make changes at any time without notice in design materials specifications prices and also for discontinued colors styles and products Consult your l...

Отзывы: