Page 3
Heating capacity input (Btuh) - Natural Gas
Model No.
-411-50
-651-125
Heating capacity output (Btuh) - Natural Gas
Heating capacity input (Btuh) - **LPG
Heating capacity output (Btuh) - **LPG
A.F.U.E. Natural/**L.P.G.
California Seasonal Efficiency Natural/**L.P.G.
ARI Standard 270 SRN (bels)
*ARI
Standard
210
Ratings
Total Cooling Capacity (Btuh)
Total unit watts
SEER (Btuh/Watts)
EER (Btuh/Watts)
Refrigerant (R-22) charge
Evaporator
Blower
Blower wheel nom. dia. x width (in.)
Motor horsepower
Air volume range (cfm)
Evaporator
Coil
Net face area (sq. ft.)
Tube dia. (in.) & Number of rows
Fins per inch
Condenser
Coil
Net face area (sq. ft.)
Tube dia. (in.) & Number of rows
Fins per inch
Condenser
Fan
Diameter (in.) & Number of blades
Air volume (cfm)
Motor horsepower
Motor watts
Gas Supply
Connections fpt (in.)
Natural
**LPG
Recommended Gas
Supply Pressure (wc. in.)
Natural
**LPG
Condensate drain size mpt (in.)
Line voltage Recommended max. fuse size (amps)
Minimum circuit ampacity
Electrical characteristics
**Optional LPG Conversion Kit
Optional Lifting Lug Kit
Optional Condenser Coil Guards
50,000
100,000
37,000
50,000
37,000
78.0%/78.0%
73.1%/73.1%
LB-62090DA
78,000
90,000
70,000
80.5%/81.0%
77.1%/77.1%
7.8
34,400
3950
9.70
8.70
4 lbs. 12 oz.
10 x 8
1/2
900 - 1500
4.10
3/8 - 2
15
8.70
3/8 - 2
20
20 - 4
2200
1/6
240
1/2
1/2
7
11
3/4
45
27.0
208/230 volts - 60 hz - 1 phase
LB-62090DB
LB-62125DA
LB-82199CC
-411-100
-511-125
-651-75
125,000
95,000
112,500
85,000
78.3%/78.5%
75.0%/75.0%
8.0
46,500
5410
9.70
8.60
5 lbs. 8 oz.
11-1/2 x 9
3/4
1200 - 2000
5.30
3/8 - 2
15
14.30
3/8 - 1.4
20
24 - 4
3880
1/4
340
1/2
1/2
7
11
3/4
60
36.0
75,000
58,000
67,500
52,000
78.4%/78.4%
72.6%/72.3%
78.3%/78.5%
75.0%/75.0%
8.0
58,500
6570
10.0
8.90
7 lbs. 0 oz.
11-1/2 x 9
3/4
1500 - 2500
6.30
3/8 - 2
15
14.30
3/8 - 2
20
24 - 4
3770
1/4
360
1/2
1/2
7
11
3/4
60
42.0
LB-62090DC
LB-62090DD
LB-62090DD
LB-82199CB
125,000
95,000
112,500
85,000
Optional Outdoor Air Dampers (manual)
OAD16-65
OAD16-41
Outer coil
Inner coil
data
GCS16R
GCS16R
GCS16R
GCS16R
GCS16R
Annual Fuel Utilization Efficiency based on DOE test procedures and FTC labeling regulations.
Sound Rating Number in accordance with ARI Standard 270.
*Rated in accordance with ARI Standard 210 and DOE; 95
F outdoor air temperature and 80
F db/67
F wb entering evaporator air.
**For LPG units a field changeover kit is required and must be ordered extra.
8.40
5.90
13.70
SPECIFICATIONS
GCS16R RESIDENTIAL UNITS