SPECIFICATIONS
ModelNo.
G40UH
−24A−045
G40UH
−36A−045
1
G40UH
−24A−070
G40UH
−36A−070
G40UH
−48B−070
G40UH
−36B−090
G40UH
−48B−090
Low NO
x
Model No. −24A−045X
− − −
− − −
−36A−070X
− − −
− − −
−48B−090X
Gas
Heating
Input− Btuh
44,000
44,000
66,000
66,000
66,000
88,000
88,000
Heating
Performance
Output− Btuh
36,000
35,900
54,100
54,100
54,000
72,100
72,100
2
AFUE
80.0%
80.0%
80.0%
80.0%
80.0%
80.0%
80.0%
Highstatic(CSA)− in.w.g.
.50
.50
.50
.50
.50
.50
.50
Temperature rise range −
_
F
35 − 65
25 − 55
40 − 70
40 − 70
25 − 55
40 − 70
40 − 70
Connections
Flue − in. (round)
4
4
4
4
4
4
4
GaspipesizeIPS− in.
1/2
1/2
1/2
1/2
1/2
1/2
1/2
Indoor
Blower
Wheelnom.dia. xwidth −in.
10 x 7
10 x 8
10 x 7
10 x 8
10 x 10
10 x 8
10 x 10
Blower
Motoroutput − hp
1/5
1/3
1/5
1/3
1/2
1/3
1/2
Tons ofadd-oncooling
1.5 − 2
2 − 3
1.5 − 2
2 − 3
2 − 4
2 − 3
3 − 4
ShippingData
lbs. − 1 package
121
126
127
132
139
146
153
Electricalcharacteristics
120 volts − 60 hertz − 1 phase (less than 12 amps)
Gas
Heating
P f
ModelNo.
1
G40UH
−36C−110
G40UH
−48C−110
G40UH
−60C−110
G40UH
−48C−135
G40UH
−60D−135
G40UH
−60D−155
g
Performance
Low NO
x
Model No.
− − −
− − −
−60C−110X
− − −
− − −
− − −
Input− Btuh
110,000
110,000
110,000
132,000
132,000
154,000
Output− Btuh
90,200
88,500
89,400
106,900
106,900
124,700
2
AFUE
80.0%
80.0%
80.0%
80.0%
80.0%
80.0%
Highstatic(CSA)− in.w.g.
.50
.50
.50
.50
.50
.50
Temperature rise range −
_
F
50 − 80
40 − 70
30 − 60
50 − 80
45 − 75
50 − 80
Connections
Flue − in. (round)
4
4
4
3
4
3
4
3
4
GaspipesizeIPS− in.
1/2
1/2
1/2
1/2
1/2
1/2
Indoor
Blower
Wheelnom.dia. xwidth −in.
10 x 8
10 x 10
11−1/2 x 10
10 x 10
11−1/2 x 10
11−1/2 x 10
Blower
Motoroutput − hp
1/3
1/2
1
1/2
1
1
Tons ofadd-oncooling
2 − 3
3 − 4
4 − 5
2.5 − 4
4 − 5
4 − 5
ShippingData
lbs. − 1 package
166
169
175
178
195
204
Electricalcharacteristics
120 volts − 60 hertz − 1 phase (less than 12 amps)
NOTE − Filters and provisions for mounting are not furnished and must be field provided.
1
Canada Only
2
Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces.
3
Flue connection on the unit is 4 in. diameter. Most applications will require 5 in. venting and field supplied 4 x 5 in. adaptor. See Venting Tables in the Installation Instructions for
detailed information.