background image

Page 2

G24E PARTS IDENTIFICATION

COIL DECK

FLUE BAFFLES

(75 only)

HEAT EXCHANGER

ASSEMBLY

BURNER ASSEMBLY

BLOWER ASSEMBLY

COMBUSTION AIR

BLOWER

FLUE BOX

FRONT LOUVERED

PANEL

DOOR INTERLOCK SWITCH

BLOWER ACCESS

PANEL

CONTROL BOARD

TRANSFORMER

PRESSURE

SWITCH

WARNING

Product contains fiberglass wool.

Disturbing the insulation in this product during
installation, maintenance, or repair will expose
you to fiberglass wool. Breathing this may
cause lung cancer. (Fiberglass wool is known to
the State of California to cause cancer.)

Fiberglass wool may also cause respiratory,
skin, and eye irritation.

To reduce exposure to this substance or for fur-
ther information, consult material safety data
sheets available from address shown below, or
contact your supervisor.

Lennox Industries Inc.
P.O. Box 799900
Dallas, TX 75379-9900

WARNING

If overheating occurs or if gas supply fails to
shut off, shut off the manual gas valve to the ap-
pliance before shutting off electrical supply.

WARNING

Do not use this furnace if any part has been
underwater. Immediately call a qualified service
technician to inspect the furnace and to replace
any part of the control system and any gas con-
trol which has been under water.

CAUTION

Before attempting to perform any service or
maintenance, turn the electrical power to unit
OFF at disconnect switch.

Содержание G24E SERIES

Страница 1: ... must be per formed by a qualified installer ser vice agency or the gas supplier Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Extinguish any open flames RETAIN THESE INSTRUCTION...

Страница 2: ...piratory skin and eye irritation To reduce exposure to this substance or for fur ther information consult material safety data sheets available from address shown below or contact your supervisor Lennox Industries Inc P O Box 799900 Dallas TX 75379 9900 WARNING If overheating occurs or if gas supply fails to shut off shut off the manual gas valve to the ap pliance before shutting off electrical su...

Страница 3: ...or because some gas is heavier than air and will settle on the floor Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion To place G24E furnace into operation G24E units are equipped with an electronic ignition sy...

Страница 4: ... ing natural gas blue yellow when burning propane gas BURNER FLAME FIGURE 4 BURNER FLAME HEAT EXCHANGER TUBE VEST PANEL FLAME APPEARS BLUE IF BURNING NAT GAS BLUE YELLOW FOR PROPANE VENTING SYSTEM INSPECTION Annually before heating season inspect furnace venting system vent cap heat exchanger and burn ers for corrosion deterioration or deposits of debris Remove any obstructions Contact your Lennox...